    Entry time: Fri Apr  3 17:39:19 2020 |  | | Author: | Andrey Starodumov |  | Category: | Module doctor |  | Subject: | M1654 | 
 |  | 
| After a protection cap glued to M1654, I observed a few strongly bent wire bonds and probably some shorts on ROC8. One (VD+) of them is even detached (on HDI side). Pads from 25/26 till 35 are affected. Nevertheless the Reception test gave the same results as before the cap gluing: grade A.
 It would be useful if Wolfram take a look and decide what to do. Silvan proposed to remove cap and repair wire-bonds.
 I could test the procedure on a dummy module (I have one) with glued cap and, if successful, do the same with M1654.
 For the moment the module is placed in Module doctor tray.
 |