Entry  Tue Apr 7 15:25:21 2020, Andrey Starodumov, Reception test, RT of M1662 failed 
    Reply  Wed Apr 8 17:17:13 2020, Andrey Starodumov, Reception test, RT of M1662 failed 
Message ID: 201     Entry time: Wed Apr 8 17:17:13 2020     In reply to: 192
Author: Andrey Starodumov 
Category: Reception test 
Subject: RT of M1662 failed 

Andrey Starodumov wrote:
Address decoding of M1662 failed in one double column of ROC4.
To be decided what to do with this module.
Currently in C* tray.

With CtrlReg=17 the grade of module is B. Still in one double column "noisy" pixels: with hits from other 3 pixels of a cluster.
Stay in C* tray. To come back later.