CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog  Not logged in ELOG logo
Entry  Thu Apr 9 14:19:40 2020, danek kotlinski, Module transfer, Modules moved to gel-pack 
    Reply  Thu Apr 9 16:13:51 2020, danek kotlinski, Module transfer, Modules moved to gel-pack 
Message ID: 205     Entry time: Thu Apr 9 16:13:51 2020     In reply to: 202
Author: danek kotlinski 
Category: Module transfer 
Subject: Modules moved to gel-pack 

danek kotlinski wrote:
The following good module class A/B have been moved to gel-packs:
1607, 1608, 1609, 1610, 1612, 1613, 1614, 1618, 1619, 1620, 1622, 1624, 1626, 1627, 1628.

The following bad module, not-working and C class have been moved to gel-packs:
1544, 1563, 1567, 1675, 1593, 1594, 1611, 1615, 1616, 1617, 1621, 1625, 1646, 1650, 1652


A few corrections to the list of bad modules:
- On April 7 M1593 has been (F)-tested with a grade B due to Rel.gain width and mean noise of a few ROCs.
- 1611 should be C* since ROC13 has not working double column (160pixels) + 27 trimbit failures but very good trimmed threshold distribution, so these 27 trimbit failures should be ignored.