Entry  Thu Apr 16 15:21:51 2020, Andrey Starodumov, Change TBM , Change TBMs on M1635, M1653, M1671 
    Reply  Mon Apr 20 15:20:07 2020, Andrey Starodumov, Reception test, Change TBMs on M1635, M1653, M1671 
Message ID: 220     Entry time: Mon Apr 20 15:20:07 2020     In reply to: 217
Author: Andrey Starodumov 
Category: Reception test 
Subject: Change TBMs on M1635, M1653, M1671 

Andrey Starodumov wrote:
M1635: no data from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change TBM0
M1671: no data from ROC12-ROC15 => change TBM0

Modules to be given to Silvan


After TBMs have been changed:
M1635: the same no data from ROC8-ROC11
M1653: reception test Grade A
M1671: the same no data from ROC12-ROC15

M1635 and M1671 to module doctor for final decision