Message ID: 227     Entry time: Thu Apr 23 13:37:29 2020
Author: Andrey Starodumov 
Category: Full test 
Subject: FT of M1556, M1557, M1559, M1560 
M1556: Grade B due to several ROCs mean noise >200e
M1557: Grade B due to several ROCs mean noise >200e and trimming failed for 60 pixel in ROC4 at -20C
M1559: Grade A
M1560: Grade B due to several ROCs mean noise >200e