CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog  Not logged in ELOG logo
Message ID: 231     Entry time: Fri Apr 24 13:59:43 2020
Author: Andrey Starodumov 
Category: Full test 
Subject: FT of M1568, M1569, M1570, M1571 
M1568: Grade B due to mean noise >200e for a few ROCs and for ROC0 RelGainWidth(=0.1) is twice larger then for other ROCs
M1569: Grade B due to mean noise >200e for a few ROCs
M1570: Grade B due to mean noise >200e for a few ROCs
M1571: Grade C due to trimming for 190 pixels failed in ROC4 at +10C. This is not real failure, the first time this module has been tested the grade was B at 10C (while trimming was done for VCal=40)

M1571 goes to C* tray. Solution: either repeat the current test or test only at +10C and merge later.
ELOG V3.1.3-7933898