Message ID: 232     Entry time: Mon Apr 27 13:23:47 2020
Author: Andrey Starodumov 
Category: Full test 
Subject: FT of M1573, M1574, M1576, M1577 
Test has been done on April 24
M1573: Grade B due to mean noise >200e for a few ROCs
M1574: Grade B due to mean noise >200e for a few ROCs and trimming failed for >100 pixels and RelGainWidth too wide for ROC0
M1576: Grade B due to mean noise >200e for a few ROCs
M1577: Grade B due RelGainWidth too wide for ROC13 at +10C, at -20C graded A!