Subject: FT of M1582, M1649, M1667 
M1582: Grade C due to trimming failure in ROC1 for 189 pixels at +10C. This is third time module restesed:
1) February 26 (trimming for VCal 40 and old PH optimization): Grade B, max 29 failed pixels and in few ROCs mean noise
2) April 27: Grade C due to trimming failure in ROC1 for 167 pixels at +10C, at -20C still max 45 failed pixels and in few ROCs mean noise
3) March 5: Grade C due to trimming failure in ROC1 for 189 pixels at +10C, at -20C trimming failure in ROC1 for 157 pixels
The module quality getting worse.

M1649: Grade B due to mean noise >200e in ROC11
M1667: Grade B due to mean noise >200e in few ROCs

M1582 is in C* tray. To be investigated.