Subject: FT of M1539, M1582, M1606 
M1539: Grade B due to mean noise >200e in few ROCs
M1582: Grade B due to mean noise >200e in few ROCs and at -20C 137 pixels in ROC1 failed trimming. For P5 could use older test results (trim parameters) of April 27 M20_1 when only 23 pixels in ROC1 failed trimming
M1606: Grade C due to 161 pixels failed trimming in ROC2 and total # of defects in this ROC 169. For P5 could use older test results (trim parameters) of March 19 M20_2 when only 36 pixels in ROC2 failed trimming or April 6 when 40 pixels failed (at all T this test has the best performance).