CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog  Not logged in ELOG logo
Message ID: 273     Entry time: Mon May 25 17:24:05 2020
Author: Andrey Starodumov 
Category: Software 
Subject: Change in MoreWeb ColumnUniformityPerColumn.py 
In file
~/L1_SW/MoReWeb/Analyse/TestResultClasses/CMSPixel/QualificationGroup/XRayHRQualification$ emacs Chips/Chip/ColumnUniformityPerColumn/ColumnUniformityPerColumn.py
the high and low rates at which double column uniformity is checked are hard coded. Rates for L2 was there. Now correction is added:
# Layer2 settings
# HitRateHigh = 150
# HitRateLow = 50
# Layer1 settings
HitRateHigh = 250
HitRateLow = 150