  69   Thu Feb 6 17:19:12 2020 Dinko FerencekReception testRT for 6 modules: 1551, 1552, 1553, 1554, 1555, 1556
Today reception test was run for 6 modules and looks OK for all module. The modules were graded as follows:

1551: A
1552: A
1553: B (Electrical grade B)
1554: A
1555: B (IV grade B)
1556: B (IV grade B)

Protective caps were glued to these modules.
  71   Fri Feb 7 19:40:27 2020 Dinko FerencekReception testRT for 6 modules: 1557, 1558, 1559, 1560, 1561, 1562
Reception test is done and all 6 modules were graded A.

Protective caps were glued to 4 modules: 1557, 1558, 1559, 1560
  78   Tue Feb 11 10:25:32 2020 Dinko FerencekReception testRT for 6 modules: 1563, 1564, 1565, 1566, 1567, 1568
Feb. 10

1563: Grade C, ROCs 8 and 10 not programmable, no obvious problems with wire bonds
1564: Grade B, I > 2 uA (2.17 uA)

Feb. 11

1565: Grade A
1566: Grade A
1567: Grade C, no data from ROCs 8-11, looks like a problem with one TBM1 core
1568: Grade A
  82   Wed Feb 12 15:40:13 2020 Dinko FerencekReception testRT for 3 modules: 1569, 1570, 1571; 1572 bad
1569: Grade A
1570: Grade A
1571: Grade B, I > 2 uA (3.09 uA)

1572 from the same batch of 4 assembled modules was not programmable and was not run through the reception test.
  83   Thu Feb 13 21:44:28 2020 Dinko FerencekReception testRT for 6 modules: 1573, 1574, 1575, 1576, 1577, 1578
1573: Grade A
1574: Grade B, I(150)/I(100) > 2 (4.63)
1575: Grade C, problem with one TBM core
1576: Grade A
1577: Grade A
1578: Grade A
  86   Fri Feb 14 14:40:59 2020 Dinko FerencekReception testRT for 2 modules: 1578, 1580
1579: Grade A
1580: Grade A
  116   Thu Mar 19 17:17:27 2020 Andrey StarodumovReception testM1609-M16012
Reception test done and caps are glued to modules M1609-M1612.
M1611 graded B due to double column failure on ROC13. Others graded A.
  118   Fri Mar 20 14:46:31 2020 Andrey StarodumovReception testM1615 failed
M1615 is programmable but "no working phases found"
Visual inspection of wire bonds - OK.
To module doctor!
  119   Fri Mar 20 14:53:52 2020 Andrey StarodumovReception testM1616 failed
ROC10 of M1616 is not programmable, no readout from ROC10 and ROC11.
Visual inspection of wire bonds - OK
To module doctor!
  120   Fri Mar 20 17:05:58 2020 Andrey StarodumovReception testM1617 failed
ROC8 of M1617 is programmable but no readout from it.
Silvan noticed that a corner of one ROC of this module is broken,
this is exactly ROC8.
  123   Sun Mar 22 13:57:25 2020 Danek KotlinskiReception testM1617 failed

Andrey Starodumov wrote:
ROC8 of M1617 is programmable but no readout from it.
Silvan noticed that a corner of one ROC of this module is broken,
this is exactly ROC8.


Interesting that the phase finding works fine, the width of the valid region is 4, so quite
good. ROC8 idneed does not give any hits but the token passed through it, so the overall
readout works fine. There re no readout errors.
The crack on the corner of this ROC is clearly visible.
I wonder how this module passed the tests in Helsinki?
  124   Sun Mar 22 14:02:20 2020 Danek KotlinskiReception testM1616 failed

Andrey Starodumov wrote:
ROC10 of M1616 is not programmable, no readout from ROC10 and ROC11.
Visual inspection of wire bonds - OK
To module doctor!


For me ROC10 is programmable.
It looks like there is not token pass through ROC11.
This affects the readout of ROCs 11 & 10.
Findphases fails because of the missing ROC10&11 readout.
  125   Sun Mar 22 14:05:20 2020 Danek KotlinskiReception testM1615 failed

Andrey Starodumov wrote:
M1615 is programmable but "no working phases found"
Visual inspection of wire bonds - OK.
To module doctor!


For me this module is working fine.
I could run phasefinding and obtained a perfect PixelAlive.
I left this module connected in the blue-box in order to run more advanced tests from home.
  127   Tue Mar 24 15:18:59 2020 Andrey StarodumovReception testM1621 failed Reception
On M1621 ROC8 is not programmable.
  128   Tue Mar 24 15:20:18 2020 Andrey StarodumovReception testM1623 failed Reception
M1623: all ROCs are programmable but no readout from ROC0-ROC3.
Visual inspection is OK.
To module doctor.
  130   Tue Mar 24 16:08:58 2020 Andrey StarodumovReception testM1625 failed Reception
M1625: all ROCs are programmable but no readout from ROC0-ROC3.
The same symptom as for M1623.
Visual inspection is OK.
To module doctor.
  133   Wed Mar 25 14:11:35 2020 Andrey StarodumovReception testRT of M1613 and M1614 on Mar 20
Reception test for these modules have been done on Mar20.
Grading A for both modules.
  136   Wed Mar 25 14:44:37 2020 Andrey StarodumovReception testRT of M1627 and M1628
Both modules graded A.
  144   Thu Mar 26 17:41:52 2020 Andrey StarodumovReception testRT of M1629-1632
All modules M1629, M1630, M1631 and M1632 graded A
  148   Fri Mar 27 14:28:14 2020 Andrey StarodumovReception testM1633 failed Reception
All ROCs are programmable but permanent DESERALISER ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK
To module doctor
ELOG V3.1.3-7933898