ID |
Date |
Author |
Category |
Subject |
69
|
Thu Feb 6 17:19:12 2020 |
Dinko Ferencek | Reception test | RT for 6 modules: 1551, 1552, 1553, 1554, 1555, 1556 |
Today reception test was run for 6 modules and looks OK for all module. The modules were graded as follows:
1551: A
1552: A
1553: B (Electrical grade B)
1554: A
1555: B (IV grade B)
1556: B (IV grade B)
Protective caps were glued to these modules. |
71
|
Fri Feb 7 19:40:27 2020 |
Dinko Ferencek | Reception test | RT for 6 modules: 1557, 1558, 1559, 1560, 1561, 1562 |
Reception test is done and all 6 modules were graded A.
Protective caps were glued to 4 modules: 1557, 1558, 1559, 1560 |
78
|
Tue Feb 11 10:25:32 2020 |
Dinko Ferencek | Reception test | RT for 6 modules: 1563, 1564, 1565, 1566, 1567, 1568 |
Feb. 10
1563: Grade C, ROCs 8 and 10 not programmable, no obvious problems with wire bonds
1564: Grade B, I > 2 uA (2.17 uA)
Feb. 11
1565: Grade A
1566: Grade A
1567: Grade C, no data from ROCs 8-11, looks like a problem with one TBM1 core
1568: Grade A |
82
|
Wed Feb 12 15:40:13 2020 |
Dinko Ferencek | Reception test | RT for 3 modules: 1569, 1570, 1571; 1572 bad |
1569: Grade A
1570: Grade A
1571: Grade B, I > 2 uA (3.09 uA)
1572 from the same batch of 4 assembled modules was not programmable and was not run through the reception test. |
83
|
Thu Feb 13 21:44:28 2020 |
Dinko Ferencek | Reception test | RT for 6 modules: 1573, 1574, 1575, 1576, 1577, 1578 |
1573: Grade A
1574: Grade B, I(150)/I(100) > 2 (4.63)
1575: Grade C, problem with one TBM core
1576: Grade A
1577: Grade A
1578: Grade A |
86
|
Fri Feb 14 14:40:59 2020 |
Dinko Ferencek | Reception test | RT for 2 modules: 1578, 1580 |
1579: Grade A
1580: Grade A |
116
|
Thu Mar 19 17:17:27 2020 |
Andrey Starodumov | Reception test | M1609-M16012 |
Reception test done and caps are glued to modules M1609-M1612.
M1611 graded B due to double column failure on ROC13. Others graded A. |
118
|
Fri Mar 20 14:46:31 2020 |
Andrey Starodumov | Reception test | M1615 failed |
M1615 is programmable but "no working phases found"
Visual inspection of wire bonds - OK.
To module doctor! |
119
|
Fri Mar 20 14:53:52 2020 |
Andrey Starodumov | Reception test | M1616 failed |
ROC10 of M1616 is not programmable, no readout from ROC10 and ROC11.
Visual inspection of wire bonds - OK
To module doctor! |
120
|
Fri Mar 20 17:05:58 2020 |
Andrey Starodumov | Reception test | M1617 failed |
ROC8 of M1617 is programmable but no readout from it.
Silvan noticed that a corner of one ROC of this module is broken,
this is exactly ROC8. |
123
|
Sun Mar 22 13:57:25 2020 |
Danek Kotlinski | Reception test | M1617 failed |
Andrey Starodumov wrote: | ROC8 of M1617 is programmable but no readout from it.
Silvan noticed that a corner of one ROC of this module is broken,
this is exactly ROC8. |
Interesting that the phase finding works fine, the width of the valid region is 4, so quite
good. ROC8 idneed does not give any hits but the token passed through it, so the overall
readout works fine. There re no readout errors.
The crack on the corner of this ROC is clearly visible.
I wonder how this module passed the tests in Helsinki?
|
124
|
Sun Mar 22 14:02:20 2020 |
Danek Kotlinski | Reception test | M1616 failed |
Andrey Starodumov wrote: | ROC10 of M1616 is not programmable, no readout from ROC10 and ROC11.
Visual inspection of wire bonds - OK
To module doctor! |
For me ROC10 is programmable.
It looks like there is not token pass through ROC11.
This affects the readout of ROCs 11 & 10.
Findphases fails because of the missing ROC10&11 readout. |
125
|
Sun Mar 22 14:05:20 2020 |
Danek Kotlinski | Reception test | M1615 failed |
Andrey Starodumov wrote: | M1615 is programmable but "no working phases found"
Visual inspection of wire bonds - OK.
To module doctor! |
For me this module is working fine.
I could run phasefinding and obtained a perfect PixelAlive.
I left this module connected in the blue-box in order to run more advanced tests from home. |
127
|
Tue Mar 24 15:18:59 2020 |
Andrey Starodumov | Reception test | M1621 failed Reception |
On M1621 ROC8 is not programmable. |
128
|
Tue Mar 24 15:20:18 2020 |
Andrey Starodumov | Reception test | M1623 failed Reception |
M1623: all ROCs are programmable but no readout from ROC0-ROC3.
Visual inspection is OK.
To module doctor. |
130
|
Tue Mar 24 16:08:58 2020 |
Andrey Starodumov | Reception test | M1625 failed Reception |
M1625: all ROCs are programmable but no readout from ROC0-ROC3.
The same symptom as for M1623.
Visual inspection is OK.
To module doctor. |
133
|
Wed Mar 25 14:11:35 2020 |
Andrey Starodumov | Reception test | RT of M1613 and M1614 on Mar 20 |
Reception test for these modules have been done on Mar20.
Grading A for both modules. |
136
|
Wed Mar 25 14:44:37 2020 |
Andrey Starodumov | Reception test | RT of M1627 and M1628 |
Both modules graded A. |
144
|
Thu Mar 26 17:41:52 2020 |
Andrey Starodumov | Reception test | RT of M1629-1632 |
All modules M1629, M1630, M1631 and M1632 graded A |
148
|
Fri Mar 27 14:28:14 2020 |
Andrey Starodumov | Reception test | M1633 failed Reception |
All ROCs are programmable but permanent DESERALISER ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK