CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog  Not logged in ELOG logo
Entry  Tue Sep 10 15:18:20 2019, Matej Roguljic, Other, Modules 1504, 1505, 1520 irradiation report 
    Reply  Fri Sep 13 15:06:51 2019, Andrey Starodumov, Other, Modules 1504, 1505, 1520 irradiation report 
       Reply  Thu Sep 19 00:52:24 2019, Dinko Ferencek, Other, Modules 1504, 1505, 1520 irradiation report ZG-FER_temp_hum_2019.08.16.-09.16.pngpixellab-main-room-1.png
Message ID: 10     Entry time: Fri Sep 13 15:06:51 2019     In reply to: 8     Reply to this: 12
Author: Andrey Starodumov 
Category: Other 
Subject: Modules 1504, 1505, 1520 irradiation report 
It was discovered that these modules were stored in Zagreb in the climatic lab where T was about +22C. These modules have been transported from Co60 irradiation facility to the lab on open air with T>30C and RH>70%. Water in the air under the cap condensated on the surface of HDIs and diluted residuals (from soldering, passivation etc), that after remains liquid or crystallised.
The irradiation itself does not course any damage. This is also confirmed by the fact that after two previous irradiations in Jan and Jul 2019 of modules and HDIs, samples remained in a good shape without any residuals on HSI surfaces. These samples have been kept in an office where T and RH were similar to the outside and not in the climatic lab.

We consider the the case is understood and closed.
ELOG V3.1.3-7933898