CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog  Not logged in ELOG logo
Entry  Fri Mar 27 18:29:53 2020, Andrey Starodumov, Full test, FT of M1629, M1630, M1631, M1632 
    Reply  Mon Mar 30 14:52:59 2020, Danek Kotlinski, Full test, FT of M1629, M1630, M1631, M1632 m1630_roc1_ph_fits.png
    Reply  Mon Mar 30 15:40:52 2020, Urs, Full test, FT of M1629, M1630, M1631, M1632 phval-curve_M1630_p10_C1.pdfphshot_vcal255.pdfpixelalive_C1.pdf
Message ID: 154     Entry time: Fri Mar 27 18:29:53 2020     Reply to this: 156   157
Author: Andrey Starodumov 
Category: Full test 
Subject: FT of M1629, M1630, M1631, M1632 
M1629: B due to mean noise at -20C
M1630: C due to ROC1 with all pixels failed of PH calibration (Gain). Both FT at -20C are A!
Should be understood and retested. Put in C* tray.
M1631: B due to mean noise in all 3 FT
M1632: A
ELOG V3.1.3-7933898