Mon Jan 18 13:53:44 2021, Andrey Starodumov, Other, DTB tests
|
M2217
--->DTB 154 (one of the red cold box setup):
- flat cable (with HV):
>adctest
clk low = -231.0 mV high= 212.0 mV amplitude = 443.0 mVpp (differential)
ctr low = -246.0 mV high= 235.0 mV amplitude = 481.0 mVpp (differential)
sda low = -250.0 mV high= 223.0 mV amplitude = 473.0 mVpp (differential)
rda low = -65.0 mV high= 48.0 mV amplitude = 113.0 mVpp (differential)
sdata1 low = -171.0 mV high= 155.0 mV amplitude = 326.0 mVpp (differential)
sdata2 low = -173.0 mV high= 149.0 mV amplitude = 322.0 mVpp (differential)
- twisted pairs cable:
several ERRORS during VthrCompCalDel and PixelAlive: ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (119) != TBM ID (120)
>adctest
clk low = -196.0 mV high= 177.0 mV amplitude = 373.0 mVpp (differential)
ctr low = -245.0 mV high= 236.0 mV amplitude = 481.0 mVpp (differential)
sda low = -249.0 mV high= 224.0 mV amplitude = 473.0 mVpp (differential)
rda low = -65.0 mV high= 55.0 mV amplitude = 120.0 mVpp (differential)
sdata1 low = -120.0 mV high= 101.0 mV amplitude = 221.0 mVpp (differential)
sdata2 low = -124.0 mV high= 102.0 mV amplitude = 226.0 mVpp (differential)
GOOD with flat cable but r/o ERRORs with twisted pairs cable
--->DTB 126 twisted pairs cable:
VthrCompCalDel test: many errors like
ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (68) != TBM ID (69),
test not converged!
>adctest
clk low = -193.0 mV high= 181.0 mV amplitude = 374.0 mVpp (differential)
ctr low = -252.0 mV high= 242.0 mV amplitude = 494.0 mVpp (differential)
sda low = -243.0 mV high= 227.0 mV amplitude = 470.0 mVpp (differential)
rda low = -67.0 mV high= 47.0 mV amplitude = 114.0 mVpp (differential)
sdata1 low = -122.0 mV high= 103.0 mV amplitude = 225.0 mVpp (differential)
sdata2 low = -120.0 mV high= 107.0 mV amplitude = 227.0 mVpp (differential)
BAD DTB!!!
--->DTB 140
VthrCompCalDel test: many errors like
ERROR:[14:19:38.397] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:19:38.398] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (4) != TBM ID (5)
test not converged!
>adctest
clk low = -194.0 mV high= 184.0 mV amplitude = 378.0 mVpp (differential)
ctr low = -248.0 mV high= 248.0 mV amplitude = 496.0 mVpp (differential)
sda low = -231.0 mV high= 230.0 mV amplitude = 461.0 mVpp (differential)
rda low = -67.0 mV high= 56.0 mV amplitude = 123.0 mVpp (differential)
sdata1 low = -123.0 mV high= 98.0 mV amplitude = 221.0 mVpp (differential)
sdata2 low = -117.0 mV high= 109.0 mV amplitude = 226.0 mVpp (differential)
BAD DTB!!!
--->DTB 172
VthrCompCalDel and PixelAlive tests: many errors like
[14:23:49.222] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:23:49.222] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (192) != TBM ID (193)
[14:24:19.902] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:24:19.902] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (72) != TBM ID (73)
but converged!
DTB WORKS but with ERRORs!!!
--->DTB 139
VthrCompCalDel and PixelAlive tests: many errors like
[14:29:57.160] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:29:57.160] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (159) != TBM ID (160)
and inefficient tornados for ROC8-15
PixelAlive: zero efficiency for all ROCs and many errors
[14:31:25.335] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:31:25.335] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (61) != TBM ID (63)
>adctest
clk low = -191.0 mV high= 194.0 mV amplitude = 385.0 mVpp (differential)
ctr low = -248.0 mV high= 254.0 mV amplitude = 502.0 mVpp (differential)
sda low = -239.0 mV high= 237.0 mV amplitude = 476.0 mVpp (differential)
rda low = -50.0 mV high= 66.0 mV amplitude = 116.0 mVpp (differential)
sdata1 low = -114.0 mV high= 113.0 mV amplitude = 227.0 mVpp (differential)
sdata2 low = -111.0 mV high= 116.0 mV amplitude = 227.0 mVpp (differential)
BAD DTB!!!
--->DTB 94
VthrCompCalDel and PixelAlive tests: many errors like
[14:38:28.017] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:38:28.017] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (133) != TBM ID (134)
and inefficient tornados for all ROC
PixelAlive: zero efficiency for all ROCs and many errors
BAD DTB!!!
--->DTB 65:
[14:44:25.326] ERROR: <PixMonitorFrame.cc/Update:L121> analog current reading unphysical
[14:44:25.326] ERROR: <PixMonitorFrame.cc/Update:L124> digital current reading unphysical
BAD DTB!!!
---> DTB 136 (from my drawer)
[14:47:23.231] ERROR: <hal.cc/status:L112> Testboard not initialized yet!
[14:47:23.231] ERROR: <PixMonitorFrame.cc/Update:L121> analog current reading unphysical
[14:47:23.231] ERROR: <PixMonitorFrame.cc/Update:L124> digital current reading unphysical
BAD DTB!!!
---> DTB 63 (from my drawer)
NO ERRORs!!!
>adctest
clk low = -148.0 mV high= 175.0 mV amplitude = 323.0 mVpp (differential)
ctr low = -245.0 mV high= 230.0 mV amplitude = 475.0 mVpp (differential)
sda low = -251.0 mV high= 225.0 mV amplitude = 476.0 mVpp (differential)
rda low = -61.0 mV high= 60.0 mV amplitude = 121.0 mVpp (differential)
sdata1 low = -121.0 mV high= 101.0 mV amplitude = 222.0 mVpp (differential)
sdata2 low = -124.0 mV high= 102.0 mV amplitude = 226.0 mVpp (differential)
VERY GOOD DTB: no errors with twisted pairs cable!!!
---> DTB 162 (from my drawer)
VthrComp test: many errors like
[14:54:07.161] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:54:07.161] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (195) != TBM ID (196)
[14:54:07.162] ERROR: <datapipe.cc/CheckEventID:L486> Channel 3 Event ID mismatch: local ID (195) != TBM ID (196)
[14:54:07.162] WARNING: Channel 2 ROC 0: Readback start marker after 15 readouts!
and inefficient tornados for ROC8-15
PixelAlive:
many errors like
[14:55:27.941] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[14:55:27.941] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (193) != TBM ID (194)
[14:55:27.941] ERROR: <datapipe.cc/CheckEventID:L486> Channel 3 Event ID mismatch: local ID (193) != TBM ID (194)
[14:55:27.941] WARNING: Channel 2 ROC 0: Readback start marker after 29 readouts!
and inneficient maps for ROC8-15
>adctest
clk low = -197.0 mV high= 178.0 mV amplitude = 375.0 mVpp (differential)
ctr low = -255.0 mV high= 236.0 mV amplitude = 491.0 mVpp (differential)
sda low = -245.0 mV high= 230.0 mV amplitude = 475.0 mVpp (differential)
rda low = -72.0 mV high= 49.0 mV amplitude = 121.0 mVpp (differential)
sdata1 low = -124.0 mV high= 97.0 mV amplitude = 221.0 mVpp (differential)
sdata2 low = -125.0 mV high= 102.0 mV amplitude = 227.0 mVpp (differential)
WORKS but with ERRORS!!!
---> DTB 170 (from my drawer)
VthrComp test: many errors like
[15:04:20.259] WARNING: Detected DESER400 trailer error bits: "CODE ERROR"
[15:04:20.259] ERROR: <datapipe.cc/CheckEventID:L486> Channel 2 Event ID mismatch: local ID (30) != TBM ID (31)
test mot converged!
BAD DTB!!!
--->DTB 18 (fixed on the red cold box setup):
NO ERRORs!!!
>adctest
clk low = -203.0 mV high= 187.0 mV amplitude = 390.0 mVpp (differential)
ctr low = -252.0 mV high= 236.0 mV amplitude = 488.0 mVpp (differential)
sda low = -248.0 mV high= 230.0 mV amplitude = 478.0 mVpp (differential)
rda low = -60.0 mV high= 48.0 mV amplitude = 108.0 mVpp (differential)
sdata1 low = -114.0 mV high= 111.0 mV amplitude = 225.0 mVpp (differential)
sdata2 low = -120.0 mV high= 109.0 mV amplitude = 229.0 mVpp (differential)
VERY GOOD DTB: no errors with twisted pairs cable!!! |
Tue Nov 19 14:10:10 2019, Andrey , Cold box tests, new modules M1533 and M1534
|
Yesterday Silvan wire bonded two new modules M1533 and M1534 that are both grade C due to high leakage current and a few ROCs with large number of defective bump bonds.
Today I run Reception1st test with IV at +10C for both modules and above features are confirmed.
The IV curves present on a MoreWeb webpage but the values of a leakage current in the table under the curve is 0A (?). May be it relates to the fact that it should be current at -150V shown,
while the voltage scan stops at -130V since one of the modules draw 98umA current at this voltage. If it so, the MoreWeb script should be corrected: the current taken at -150V or if voltage
is lower then it is taken at the last (highest) value.
Tomorrow a FullQualification will be run on both modules. |
Wed Nov 20 16:53:50 2019, Andrey , Full test, M1533 and M1534 FullQualification
|
FullQualification of two modules M1533 and M1534 has been done. Full time of the test is about 7hrs.
Test included: FT@-10C, IV@-10, 2Cycles from -10C up to +10C, FT@-10C, IV@-10C, Ft@1-C and IV@10C.
No issues observed.
To be understood:
1) why SCurves results (noise) empty?
2) why the number of ROCs with defects always -1?
|
|