Entry  Fri Mar 27 18:29:53 2020, Andrey Starodumov, Full test, FT of M1629, M1630, M1631, M1632 
    Reply  Mon Mar 30 14:52:59 2020, Danek Kotlinski, Full test, FT of M1629, M1630, M1631, M1632 m1630_roc1_ph_fits.png
    Reply  Mon Mar 30 15:40:52 2020, Urs, Full test, FT of M1629, M1630, M1631, M1632 phval-curve_M1630_p10_C1.pdfphshot_vcal255.pdfpixelalive_C1.pdf
Message ID: 157     Entry time: Mon Mar 30 15:40:52 2020     In reply to: 154
Author: Urs 
Category: Full test 
Subject: FT of M1629, M1630, M1631, M1632 
M1630 is interesting because (I am using my terminology in the following) for the test at T=+10C ROC1 fails the PH optimization test and by consequence the gain/pedestal test is also failed.

The PH optimization test is failed because the minimum pixel on which the test is based is a 'dead' pixel (according to the PixelAlive test), but unfortunately has hits in the initial PH map. As a result the phscale and phoffset for this ROC are not optimal and this is seen in the gain/pedestal fits.

Please find the plots attached from the T=+10 tests.
Attachment 1: phval-curve_M1630_p10_C1.pdf  41 kB  Uploaded Mon Mar 30 16:47:18 2020  | Show | Hide all | Show all
Attachment 2: phshot_vcal255.pdf  33 kB  Uploaded Mon Mar 30 16:47:42 2020  | Hide | Hide all | Show all
phshot_vcal255.pdf
Attachment 3: pixelalive_C1.pdf  27 kB  Uploaded Mon Mar 30 16:47:50 2020  | Show | Hide all | Show all