| ID | 
Date | 
Author  | 
Category | 
Subject | 
Text | 
  | 
| 
  190  
 | 
Mon Apr  6 17:18:02 2020 | 
Andrey Starodumov | Full test | FT of M1606, M1630, M1655, M1566 | M1606: B due to mean noise of several ROCs> 
200e
 
M1639: C* due to failure many pixels of ROC1 | 
   | 
| 
  191  
 | 
Tue Apr  7 14:26:48 2020 | 
Andrey Starodumov | Reception test | RT of M1567 failed | After exchange of TBM1 the results is the 
same:
 
 | 
   | 
| 
  192  
 | 
Tue Apr  7 15:25:21 2020 | 
Andrey Starodumov | Reception test | RT of M1662 failed | Address decoding of M1662 failed in one double 
column of ROC4.
 
To be decided what to do with this module.
 | 
   | 
| 
  193  
 | 
Tue Apr  7 16:57:01 2020 | 
Andrey Starodumov | Full test | FT of M1593, M1658, M1659, M1660 | M1593: B due to Rel.gain width and mean noise 
of a few ROCs
 
M1658: B due to threshold and mean noise | 
   | 
| 
  194  
 | 
Tue Apr  7 17:59:27 2020 | 
Andrey Starodumov | HDI test | 6 HDIs tested | HDIs
 
2030, 2031, 1021, 1022, 1023, 1035 
 
are tested. All OK. | 
   | 
| 
  195  
 | 
Tue Apr  7 18:02:07 2020 | 
Andrey Starodumov | Reception test | RT of 1654 | After Silvan removed a cap and re-bonded broken 
and bent wires M1654 again has been tested.
 
RT grade is A.
 | 
   | 
| 
  196  
 | 
Wed Apr  8 13:40:45 2020 | 
Andrey Starodumov | Reception test | RT of M1625 failed | Silvan substituted TBM on this module.
 
Now ROC0 does not have hits.
 
Grade C, goes to "Bad" tray. | 
   | 
| 
  197  
 | 
Wed Apr  8 13:43:15 2020 | 
Andrey Starodumov | Reception test | RT of M1623 failed | M1623: all ROCs are programmable but no readout 
from ROC8-ROC11.
 
Visual inspection is OK.
 | 
   | 
| 
  198  
 | 
Wed Apr  8 15:02:37 2020 | 
Andrey Starodumov | Software | Change of CrtlReg for RT | So far in a blue box for RT tbm10d_procv3 
parameters were used. 
 
This is wrong, since CtrlReg=9 is better | 
   | 
| 
  199  
 | 
Wed Apr  8 15:20:38 2020 | 
Andrey Starodumov | Reception test | RT of M1665 | With CtrlReg=9 RT grade was B due to 90 noisy 
pixels in ROC5.
 
Noisy in this case means that one pixel in | 
   | 
| 
  200  
 | 
Wed Apr  8 17:09:05 2020 | 
Andrey Starodumov | Full test | FT of M1572, M1661, M1663, M1664 | M1572: Grade B due to mean noise of ROC4 211 
electrons
 
M1661: Grade B due to mean noise of a few | 
   | 
| 
  201  
 | 
Wed Apr  8 17:17:13 2020 | 
Andrey Starodumov | Reception test | RT of M1662 failed | [quote="Andrey Starodumov"]Address decoding 
of M1662 failed in one double column of ROC4.
 
To be decided what to do with this module.
 | 
   | 
| 
  203  
 | 
Thu Apr  9 14:36:10 2020 | 
Andrey Starodumov | Reception test | RT of M1669 and M1670 | Both modules graded A. | 
   | 
| 
  204  
 | 
Thu Apr  9 14:49:07 2020 | 
Andrey Starodumov | Reception test | RT of M1650 failed | Module has been tested on April 2nd.
 
Under Molex connector in ROC12 471 dead or 
noisy pixels.
 | 
   | 
| 
  206  
 | 
Thu Apr  9 17:24:49 2020 | 
Andrey Starodumov | Full test | FT of M1654, M1665, M1666, M1667 | M1654: Grade A
 
M1665: Grade B due to noisy pixels in ROC5. 
To be checked by module doctor!
 | 
   | 
| 
  207  
 | 
Thu Apr  9 17:36:31 2020 | 
Andrey Starodumov | Reception test | RT of M1671 failed | ROC12-ROC15 no hits.
 
A candidate to TBM0 substitution, hence Grade 
C*.
 | 
   | 
| 
  208  
 | 
Thu Apr  9 17:43:54 2020 | 
Andrey Starodumov | HDI test | 4 HDIa tested | HDIs 3029, 3031, 3032, 4042 passed tests. 
All OK. | 
   | 
| 
  209  
 | 
Tue Apr 14 15:49:05 2020 | 
Andrey Starodumov | Reception test | RT of M1623, M1657, M1673, M1674 | M1623: Grade A, should be B due to 71 bump 
defects in ROC4 
 
M1657: Grade B, due to 51 dead pixels in | 
   | 
| 
  210  
 | 
Tue Apr 14 16:54:31 2020 | 
Andrey Starodumov | Other | M1633 cable disconnected | We do not have any more module holders. 
 
M1633 was in "Module doctor" tray.
 
I took module off the holder and put it in | 
   | 
| 
  211  
 | 
Tue Apr 14 17:19:44 2020 | 
Andrey Starodumov | Full test | FT of M1668, M1669, M1670, M1672 | M1668: Grade B due to mean noise >200e for 
several ROCs
 
M1669: Grade B due to ROC2 mean noise >200e
 | 
   |