    Reply  Wed Mar 25 18:31:46 2020, Andrey Starodumov, Re-grading, Reanalised test results 
[quote="Andrey Starodumov"]Test resulsts of several modules have been re-analised without grading on trimbit failure. 
M1614: C->B
M1613: C->A
Entry  Wed Mar 25 18:40:53 2020, Andrey Starodumov, Full test, FT of M1599, M1613, M1624, M1616 
M1599: B due to leakage current at +10 (2-3umA)
M1613: B due to a few pixels with bad trimmed threshold
M1624: B due to a few ROCs with mean noise>200electrons
Entry  Thu Mar 26 17:41:52 2020, Andrey Starodumov, Reception test, RT of M1629-1632 
All modules M1629, M1630, M1631 and M1632 graded A
Entry  Thu Mar 26 17:43:06 2020, Andrey Starodumov, HDI test, 6+1 HDI tested 
HDIs: 6021, 3014, 2005, 2009, 2006 and 2010 are OK
HDI 6024 failed: SDA0 and SDA2 on Ch1 missing
Entry  Thu Mar 26 17:45:15 2020, Andrey Starodumov, Full test, FT of M1545, M1557, M1627, M1628 
Retested M1545: C->B (to be correct on the MoreWeb summary page)
Retested 1557: C->C in one ROC >160 pixels failed to be trimmed [B]Module placed in a tray C*[/B]
1627: B
Entry  Fri Mar 27 14:28:14 2020, Andrey Starodumov, Reception test, M1633 failed Reception 
All ROCs are programmable but permanent DESERALISER ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK
To module doctor
Entry  Fri Mar 27 14:32:11 2020, Andrey Starodumov, HDI test, List of suspicious HDIs 
Here are HDIs that the first time tested showed 500-600V measured on the pin or directly on the HDI pad instead of 800V:
5006, 5007, 2005
3014, 3017, 3019, 6021
Entry  Fri Mar 27 14:46:04 2020, Andrey Starodumov, Module doctor, Wolfram's summay from Mar 25 
M1542     nothing on sdata3 (12-15), bad output or wire-bond
M1544     ROC15 timing off, can be made to work (roc 15 vdig 11, ..), but probably not usable for the detector
M1545     full readout, ok, upgraded to C*
    Reply  Fri Mar 27 16:41:16 2020, Andrey Starodumov, Module doctor, Wolfram's summay from Mar 25 
[quote="Andrey Starodumov"]M1542     nothing on sdata3 (12-15), bad output or wire-bond
M1544     ROC15 timing off, can be made to work (roc 15 vdig 11, ..), but probably not usable for the detector
M1545     full readout, ok, upgraded to C*
Entry  Fri Mar 27 17:27:09 2020, Andrey Starodumov, Reception test, M1635 failed Reception 
All ROCs are programmable but DESER400 trailer error bits: "NO DATA" or "IDLE DATA".
ROC8-11 are affected (no data)
Visual inspection is OK
Entry  Fri Mar 27 18:28:34 2020, Andrey Starodumov, Full test, 4 HDIs tested 
HDIs 5020, 5018, 1044 and 1041 are OK
Entry  Fri Mar 27 18:29:53 2020, Andrey Starodumov, Full test, FT of M1629, M1630, M1631, M1632 
M1629: B due to mean noise at -20C
M1630: C due to ROC1 with all pixels failed of PH calibration (Gain). Both FT at -20C are A!
Should be understood and retested. Put in C* tray.
Entry  Mon Mar 30 16:46:59 2020, Andrey Starodumov, DB, Sensors missing in Advacam spreadsheet 
Dinko noticed that several sensors are missing in Advacam spreadsheet:
- 381785-03-3 used for M1586
- 381783-02-1 used for M1617
Entry  Mon Mar 30 17:40:35 2020, Andrey Starodumov, HDI test, 3+2 HDIs (re-)tested 
For 3 HDIs: 3014, 3017, 6021, HV has been re-measured. In all cases 790V is measured with 800V supplied.
2 HDIs: 1026, 5022 were tested. Both  OK.
All 5 HDIs will be used in module assembly.
Entry  Mon Mar 30 17:49:31 2020, Andrey Starodumov, Reception test, RT of M1637-1640 
All modules: M1637, M1638, M1639, M1649, are graded A.
 
Entry  Tue Mar 31 08:21:39 2020, Andrey Starodumov, Full test, FT of 1558, 1606, 1634, 1636 on Mar 30 
M1558: B 
M1606: C again due to trimmed threshold for 189 pixels of ROC2 at -20C. Second time at -20C and at +10C the number of failed pixels is 90+, hence grading
is B.
Entry  Tue Mar 31 17:32:47 2020, Andrey Starodumov, Reception test, RT of M1641-M1644 
All modules graded A.
Entry  Tue Mar 31 17:33:37 2020, Andrey Starodumov, Reception test, RT of M1546 
This is a module with a broken TBM. Silvan put a new one on top of the broken TBM.
The module is graded A after reception test.
I'm still not sure that wire-bonds of the new TBM is lower than capacitors. I'll try to glue a cap tomorrow
Entry  Tue Mar 31 18:14:47 2020, Andrey Starodumov, HDI test, 3 HDI tested 
HDIs: 1027, 5002, 5003 are tested. All OK.
Entry  Tue Mar 31 18:23:18 2020, Andrey Starodumov, Full test, FT of M1637, M1638, M1639, M1640 
M1637: C. Graded C due to not completed first test at -20C. Urs has reported issues. The second -20C after T-Cycle and test at +10C are graded A.
Tomorrow I'll upgrade this module manually to A
M1638: A