  139  
 | 
Wed Mar 25 18:31:46 2020 | 
Andrey Starodumov | Re-grading | Reanalised test results | 
 | Andrey Starodumov wrote: |  Test resulsts of several modules have been re-analised without grading on trimbit failure.  
M1614: C->B 
M1613: C->A 
M1609: C->B 
M1618: B->A 
M1612: B->B 
M1610: B->B 
M1608: C->B 
M1606: C->C (too many badly trimmed pixels) 
M1605: C->B 
 
Most of all B grading and one C are due to badly trimmed pixels. The threshold after trimming usually has 3(!) separated peaks. 
We should understand this feature. |  
  
 
More modules have been re-analysed: 
1604: C->B 
1603: C->B 
1602: C->B 
1601: B->A 
1545: C->C (too many pixels on ROC14 are badly trimmed, to be retested tomorrow) | 
| 
  140  
 | 
Wed Mar 25 18:40:53 2020 | 
Andrey Starodumov | Full test | FT of M1599, M1613, M1624, M1616 | 
M1599: B due to leakage current at +10 (2-3umA) 
M1613: B due to a few pixels with bad trimmed threshold 
M1624: B due to a few ROCs with mean noise>200electrons 
M1626: A | 
| 
  144  
 | 
Thu Mar 26 17:41:52 2020 | 
Andrey Starodumov | Reception test | RT of M1629-1632 | 
| All modules M1629, M1630, M1631 and M1632 graded A | 
| 
  145  
 | 
Thu Mar 26 17:43:06 2020 | 
Andrey Starodumov | HDI test | 6+1 HDI tested | 
HDIs: 6021, 3014, 2005, 2009, 2006 and 2010 are OK 
HDI 6024 failed: SDA0 and SDA2 on Ch1 missing 
 
Looks like lower than 800V measured effect relates to the cable. 
After cable has been changed all measurements 790V | 
| 
  146  
 | 
Thu Mar 26 17:45:15 2020 | 
Andrey Starodumov | Full test | FT of M1545, M1557, M1627, M1628 | 
Retested M1545: C->B (to be correct on the MoreWeb summary page) 
Retested 1557: C->C in one ROC >160 pixels failed to be trimmed Module placed in a tray C* 
1627: B 
1628: B 
 
All B grades due to high (>200electons) mean noise.  | 
| 
  148  
 | 
Fri Mar 27 14:28:14 2020 | 
Andrey Starodumov | Reception test | M1633 failed Reception | 
All ROCs are programmable but permanent DESERALISER ERROR, Ch6 and Ch7 event ID mismatch. 
Visual inspection is OK 
To module doctor | 
| 
  149  
 | 
Fri Mar 27 14:32:11 2020 | 
Andrey Starodumov | HDI test | List of suspicious HDIs | 
Here are HDIs that the first time tested showed 500-600V measured on the pin or directly on the HDI pad instead of 800V: 
5006, 5007, 2005 
3014, 3017, 3019, 6021 
 
I put them in the box called "For Wolfram ...." on the Wolfram's desk in the lab. 
 
Nevertheless, I think this is an artificial issue that mmight be caused by a cable. I retested 5006, 5007 and 2005 with a new 
cable and in all cases measured HV=790V what is normal. | 
| 
  150  
 | 
Fri Mar 27 14:46:04 2020 | 
Andrey Starodumov | Module doctor | Wolfram's summay from Mar 25 | 
M1542     nothing on sdata3 (12-15), bad output or wire-bond 
M1544     ROC15 timing off, can be made to work (roc 15 vdig 11, ..), but probably not usable for the detector 
M1545     full readout, ok, upgraded to C* 
M1546     TBM1 output alpha broken (sdata1) => replace TBM1 
M1563     ROC 8 thinks he is roc 10  ==> check address wire bond on roc 8? 
M1567     roc 11 missing, sdata2 (b-channel) 
M1572     sticker says : both TBMs broken, no SDA  => replace both TBMs? 
M1575     no readout from rocs 0,1 (tbm0b, sdata4), all rocs programmable ==> TODO check CTR roc 0 
M1593     tbm0, core B (roc 0-3), no decodable output, core/stack working ok, output beta+ high ~ 2V 
M1594     roc 0 dead 
M1615     nothing on sdata 3 (12-15), very bad cable (corrosion?) re-running with new cable 
M1616     ROC 10 not programmable, no roc headers on sdata2 (b) ==> TODO check clock to roc 10 
M1617     readout but no hits in ROC 8, mechanical damage on chip edge 
M1621     ROC 8 not programmable, no roc headers or tbm trailers on sdata2a (tbm1b) ==> TODO check clock on ROC 8 
M1623     probably no cal-trig-reset to roc 0-3 
M1625     definitely not cal-trig-reset to roc 0-3 (CTR- at 0V), damaged when trying to pull wire-bonds | 
| 
  151  
 | 
Fri Mar 27 16:41:16 2020 | 
Andrey Starodumov | Module doctor | Wolfram's summay from Mar 25 | 
 | Andrey Starodumov wrote: |  M1542     nothing on sdata3 (12-15), bad output or wire-bond 
M1544     ROC15 timing off, can be made to work (roc 15 vdig 11, ..), but probably not usable for the detector 
M1545     full readout, ok, upgraded to C* 
M1546     TBM1 output alpha broken (sdata1) => replace TBM1 
M1563     ROC 8 thinks he is roc 10  ==> check address wire bond on roc 8? 
M1567     roc 11 missing, sdata2 (b-channel) 
M1572     sticker says : both TBMs broken, no SDA  => replace both TBMs? 
M1575     no readout from rocs 0,1 (tbm0b, sdata4), all rocs programmable ==> TODO check CTR roc 0 
M1593     tbm0, core B (roc 0-3), no decodable output, core/stack working ok, output beta+ high ~ 2V 
M1594     roc 0 dead 
M1615     nothing on sdata 3 (12-15), very bad cable (corrosion?) re-running with new cable 
M1616     ROC 10 not programmable, no roc headers on sdata2 (b) ==> TODO check clock to roc 10 
M1617     readout but no hits in ROC 8, mechanical damage on chip edge 
M1621     ROC 8 not programmable, no roc headers or tbm trailers on sdata2a (tbm1b) ==> TODO check clock on ROC 8 
M1623     probably no cal-trig-reset to roc 0-3 
M1625     definitely not cal-trig-reset to roc 0-3 (CTR- at 0V), damaged when trying to pull wire-bonds |  
  
  
M1542 is fully OK. It's graded C due to very broad relative Gain distribution of ROC6. 
If we will have time it would be useful to take a close look at this module. 
It remains graded C. | 
| 
  152  
 | 
Fri Mar 27 17:27:09 2020 | 
Andrey Starodumov | Reception test | M1635 failed Reception | 
All ROCs are programmable but DESER400 trailer error bits: "NO DATA" or "IDLE DATA". 
ROC8-11 are affected (no data) 
Visual inspection is OK 
To module doctor | 
| 
  153  
 | 
Fri Mar 27 18:28:34 2020 | 
Andrey Starodumov | Full test | 4 HDIs tested | 
| HDIs 5020, 5018, 1044 and 1041 are OK | 
| 
  154  
 | 
Fri Mar 27 18:29:53 2020 | 
Andrey Starodumov | Full test | FT of M1629, M1630, M1631, M1632 | 
M1629: B due to mean noise at -20C 
M1630: C due to ROC1 with all pixels failed of PH calibration (Gain). Both FT at -20C are A! 
Should be understood and retested. Put in C* tray. 
M1631: B due to mean noise in all 3 FT 
M1632: A | 
| 
  158  
 | 
Mon Mar 30 16:46:59 2020 | 
Andrey Starodumov | DB | Sensors missing in Advacam spreadsheet | 
Dinko noticed that several sensors are missing in Advacam spreadsheet: 
- 381785-03-3 used for M1586 
- 381783-02-1 used for M1617 
- 381783-03-3 used for M1618 
- 350853-16-1 used for M1619 
 
It means that information about about ROCs used for these modules is missing in the Module_Assembly spreadsheet.  | 
| 
  159  
 | 
Mon Mar 30 17:40:35 2020 | 
Andrey Starodumov | HDI test | 3+2 HDIs (re-)tested | 
For 3 HDIs: 3014, 3017, 6021, HV has been re-measured. In all cases 790V is measured with 800V supplied. 
2 HDIs: 1026, 5022 were tested. Both  OK. 
All 5 HDIs will be used in module assembly. | 
| 
  160  
 | 
Mon Mar 30 17:49:31 2020 | 
Andrey Starodumov | Reception test | RT of M1637-1640 | 
All modules: M1637, M1638, M1639, M1649, are graded A. 
  | 
| 
  162  
 | 
Tue Mar 31 08:21:39 2020 | 
Andrey Starodumov | Full test | FT of 1558, 1606, 1634, 1636 on Mar 30 | 
M1558: B  
M1606: C again due to trimmed threshold for 189 pixels of ROC2 at -20C. Second time at -20C and at +10C the number of failed pixels is 90+, hence grading is B. 
We could manually upgrade this module to B. 
M1634: A 
M1636: A | 
| 
  165  
 | 
Tue Mar 31 17:32:47 2020 | 
Andrey Starodumov | Reception test | RT of M1641-M1644 | 
| All modules graded A. | 
| 
  166  
 | 
Tue Mar 31 17:33:37 2020 | 
Andrey Starodumov | Reception test | RT of M1546 | 
This is a module with a broken TBM. Silvan put a new one on top of the broken TBM. 
The module is graded A after reception test. 
I'm still not sure that wire-bonds of the new TBM is lower than capacitors. I'll try to glue a cap tomorrow 
to see whether we could substitute TBMs on another 6 modules with broken TBMs. | 
| 
  168  
 | 
Tue Mar 31 18:14:47 2020 | 
Andrey Starodumov | HDI test | 3 HDI tested | 
| HDIs: 1027, 5002, 5003 are tested. All OK. | 
| 
  169  
 | 
Tue Mar 31 18:23:18 2020 | 
Andrey Starodumov | Full test | FT of M1637, M1638, M1639, M1640 | 
M1637: C. Graded C due to not completed first test at -20C. Urs has reported issues. The second -20C after T-Cycle and test at +10C are graded A. 
Tomorrow I'll upgrade this module manually to A 
M1638: A 
M1639: B Due to B at first -20C test. ROC8 mean noise >200electrons. Second -20C and at +10C both are graded A 
M1640: B All three FT are B due to several ROCs mean noise >200electrons  |