  228   Thu Apr 23 17:26:51 2020 Andrey StarodumovFull testFT of M1561, M1564, M1565, M1566M1561: Grade B due to several ROCs mean noise
>200e
M1564: Grade B due to two ROCs mean noise
  
  227   Thu Apr 23 13:37:29 2020 Andrey StarodumovFull testFT of M1556, M1557, M1559, M1560M1556: Grade B due to several ROCs mean noise
>200e
M1557: Grade B due to several ROCs mean noise
  
  226   Thu Apr 23 13:34:52 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653[quote="Andrey Starodumov"][quote="Andrey
Starodumov"]
M1542: Grade C due to massive (>1000pixels
  
  225   Wed Apr 22 17:41:11 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653[quote="Andrey Starodumov"]
M1542: Grade C due to massive (>1000pixels
in total) trimming failures at -20C in ROC11,14,15.
  
  224   Wed Apr 22 17:28:42 2020 Andrey StarodumovHDI test11 HDIs testedAfter keeping HDIs in a very high RH for a
dew hours (24 is fine) became flat and could
be fixed on HDI holder by vacuum.
  
  223   Tue Apr 21 17:39:48 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653M1542: Grade C due to massive (>1000pixels
in total) trimming failures at -20C in ROC11,14,15.
There was no such problem at previous test
  
  222   Tue Apr 21 15:34:57 2020 Andrey StarodumovGeneralRetesting starts todayFrom today we will retest modules that have
been tested with pXar SW versions earlier
than March 18.
  
  221   Mon Apr 20 17:09:12 2020 Andrey StarodumovHDI test4 HDIs testedAfter staying in 90%+ RH 2 HDIs became flat.
The first one was easy to mount on an HDI
holder.
  
  220   Mon Apr 20 15:20:07 2020 Andrey StarodumovReception testChange TBMs on M1635, M1653, M1671[quote="Andrey Starodumov"]M1635: no data
from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change
  
  219   Fri Apr 17 18:05:45 2020 Andrey StarodumovFull testFT of M1542, M1557, M1630, M1649 only at +10CM1542 has grade C for relative gain width.
Was tested with early versions of test SW
with trim VCal=40 and not yet optimized PH
  
  218   Thu Apr 16 17:31:16 2020 Andrey StarodumovFull testFT of M1662, M1675, M1676M1662: Grade C due to failure of ROC4 in almost
all tests: PixelAlive, PH calibration etc
Should be investigated and retested. At Reception
  
  217   Thu Apr 16 15:21:51 2020 Andrey StarodumovChange TBM Change TBMs on M1635, M1653, M1671M1635: no data from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change
TBM0
  
  216   Wed Apr 15 17:33:53 2020 danek kotlinskiModule transfermove 4 modules to gel-packs[quote="danek kotlinski"]Moved to gel-apcks:
1629 B
1631 B
  
  215   Wed Apr 15 17:26:46 2020 Andrey StarodumovFull testFT of M1623, M1657, M1673, M1674M1623: Grade B due to rel gain width, in ROC4
74 pixels failed trimming (Threshold) and
mean noise >200e
  
  214   Wed Apr 15 17:14:42 2020 danek kotlinskiModule transfermove 4 modules to gel-packsMoved to gel-apcks:
1629 B
1631 B
  
  213   Wed Apr 15 08:48:09 2020 danek kotlinskiModule doctorWolfram's tests from 14/4/20two of are fixed and can be re-tested
M1623   tbm bond
M1657   bond roc 15
  
  212   Tue Apr 14 17:29:46 2020 Andrey StarodumovGeneralROC4 or ROC12 defectsStarting from M1650 almost every module has
a cluster of dead pixels or broken bump bonds
on
  
  211   Tue Apr 14 17:19:44 2020 Andrey StarodumovFull testFT of M1668, M1669, M1670, M1672M1668: Grade B due to mean noise >200e for
several ROCs
M1669: Grade B due to ROC2 mean noise >200e
  
  210   Tue Apr 14 16:54:31 2020 Andrey StarodumovOtherM1633 cable disconnectedWe do not have any more module holders. 
M1633 was in "Module doctor" tray.
I took module off the holder and put it in
  
  209   Tue Apr 14 15:49:05 2020 Andrey StarodumovReception testRT of M1623, M1657, M1673, M1674M1623: Grade A, should be B due to 71 bump
defects in ROC4 
M1657: Grade B, due to 51 dead pixels in
  