  208  
 | 
Thu Apr  9 17:43:54 2020 | 
Andrey Starodumov | HDI test | 4 HDIa tested |  | HDIs 3029, 3031, 3032, 4042 passed tests. All OK. |  
| 
  207  
 | 
Thu Apr  9 17:36:31 2020 | 
Andrey Starodumov | Reception test | RT of M1671 failed |  ROC12-ROC15 no hits. 
A candidate to TBM0 substitution, hence Grade C*. 
To Module doctor1 |  
| 
  206  
 | 
Thu Apr  9 17:24:49 2020 | 
Andrey Starodumov | Full test | FT of M1654, M1665, M1666, M1667 |  M1654: Grade A 
M1665: Grade B due to noisy pixels in ROC5. To be checked by module doctor! 
M1666: Grade B due to mean noise of several chips > 200 electrons. Again on ROC12 there is a cluster of 31 dead bumps! 
M1667: Grade B due to mean noise of several chips > 200 electrons. Again on ROC12 there is a cluster of 41 dead bumps! 
 
M1665 goes to Module doctor! |  
| 
  205  
 | 
Thu Apr  9 16:13:51 2020 | 
danek kotlinski | Module transfer | Modules moved to gel-pack |  
 | danek kotlinski wrote: |  The following good module class A/B have been moved to gel-packs: 
1607, 1608, 1609, 1610, 1612, 1613, 1614, 1618, 1619, 1620, 1622, 1624, 1626, 1627, 1628. 
 
The following bad module, not-working  and C class have been moved to gel-packs: 
1544, 1563, 1567, 1675, 1593, 1594, 1611, 1615, 1616, 1617, 1621, 1625, 1646, 1650, 1652 |  
  
 
A few corrections to the list of bad modules: 
- On April 7 M1593 has been (F)-tested with a grade B due to Rel.gain width and mean noise of a few ROCs. 
 - 1611 should be C* since ROC13 has not working double column (160pixels) + 27 trimbit failures but very good trimmed threshold distribution, so these 27 trimbit failures should be ignored. |  
| 
  204  
 | 
Thu Apr  9 14:49:07 2020 | 
Andrey Starodumov | Reception test | RT of M1650 failed |  Module has been tested on April 2nd. 
Under Molex connector in ROC12 471 dead or noisy pixels. 
Grade C. |  
| 
  203  
 | 
Thu Apr  9 14:36:10 2020 | 
Andrey Starodumov | Reception test | RT of M1669 and M1670 |  | Both modules graded A. |  
| 
  202  
 | 
Thu Apr  9 14:19:40 2020 | 
danek kotlinski | Module transfer | Modules moved to gel-pack |  The following good module class A/B have been moved to gel-packs: 
1607, 1608, 1609, 1610, 1612, 1613, 1614, 1618, 1619, 1620, 1622, 1624, 1626, 1627, 1628. 
 
The following bad module, not-working  and C class have been moved to gel-packs: 
1544, 1563, 1567, 1675, 1593, 1594, 1611, 1615, 1616, 1617, 1621, 1625, 1646, 1650, 1652 |  
| 
  201  
 | 
Wed Apr  8 17:17:13 2020 | 
Andrey Starodumov | Reception test | RT of M1662 failed |  
 | Andrey Starodumov wrote: |  Address decoding of M1662 failed in one double column of ROC4. 
To be decided what to do with this module. 
Currently in C* tray. |  
  
With CtrlReg=17 the grade of module is B. Still in one double column "noisy" pixels: with hits from other 3 pixels of a cluster. 
Stay in C* tray. To come back later.  |  
| 
  200  
 | 
Wed Apr  8 17:09:05 2020 | 
Andrey Starodumov | Full test | FT of M1572, M1661, M1663, M1664 |  M1572: Grade B due to mean noise of ROC4 211 electrons 
M1661: Grade B due to mean noise of a few ROCs > 200 electrons and in ROC12 44 pixels failed threshold cut 
M1663: Grade B due to mean noise of a few ROCs > 200 electrons 
M1664: Grade B due to mean noise of a few ROCs > 200 electrons and in ROC12 44 pixels failed threshold cut |  
| 
  199  
 | 
Wed Apr  8 15:20:38 2020 | 
Andrey Starodumov | Reception test | RT of M1665 |  With CtrlReg=9 RT grade was B due to 90 noisy pixels in ROC5. 
Noisy in this case means that one pixel in a 2x2 cluster in a few column got 40 hits instead of 10. 
With CtrlReg=17 this problem gone. RT grade is A. |  
| 
  198  
 | 
Wed Apr  8 15:02:37 2020 | 
Andrey Starodumov | Software | Change of CrtlReg for RT |  So far in a blue box for RT tbm10d_procv3 parameters were used.  
This is wrong, since CtrlReg=9 is better for -20C while for +10 or higher T 
CtrlReg=17 is better.  
From now on for RT tbm10d_procv4 will be used. |  
| 
  197  
 | 
Wed Apr  8 13:43:15 2020 | 
Andrey Starodumov | Reception test | RT of M1623 failed |  M1623: all ROCs are programmable but no readout from ROC8-ROC11. 
Visual inspection is OK. 
To module doctor.  |  
| 
  196  
 | 
Wed Apr  8 13:40:45 2020 | 
Andrey Starodumov | Reception test | RT of M1625 failed |  Silvan substituted TBM on this module. 
Now ROC0 does not have hits. 
Grade C, goes to "Bad" tray. |  
| 
  195  
 | 
Tue Apr  7 18:02:07 2020 | 
Andrey Starodumov | Reception test | RT of 1654 |  After Silvan removed a cap and re-bonded broken and bent wires M1654 again has been tested. 
RT grade is A. 
Protection cap to be glued and to be (F)tested. |  
| 
  194  
 | 
Tue Apr  7 17:59:27 2020 | 
Andrey Starodumov | HDI test | 6 HDIs tested |  HDIs 
2030, 2031, 1021, 1022, 1023, 1035  
are tested. All OK. |  
| 
  193  
 | 
Tue Apr  7 16:57:01 2020 | 
Andrey Starodumov | Full test | FT of M1593, M1658, M1659, M1660 |  M1593: B due to Rel.gain width and mean noise of a few ROCs 
M1658: B due to threshold and mean noise of ROC15 
M1659: B due to threshold and mean noise of a few ROCs 
M1660: C due to 172 pixels failed Threshold (trimmed) on ROC7 only at second -20C, the first -20C and +10C trimming threshold is OK for this chip 
 
M1660 to C* tray and retest with all other modules after production, |  
| 
  192  
 | 
Tue Apr  7 15:25:21 2020 | 
Andrey Starodumov | Reception test | RT of M1662 failed |  Address decoding of M1662 failed in one double column of ROC4. 
To be decided what to do with this module. 
Currently in C* tray. |  
| 
  191  
 | 
Tue Apr  7 14:26:48 2020 | 
Andrey Starodumov | Reception test | RT of M1567 failed |  After exchange of TBM1 the results is the same: 
 
WAS:  
1567: Grade C, no data from ROCs 8-11, looks like a problem with one TBM1 core 
 
NOW: 
-during ThrComp-CalDel scan: WARNING: Detected DESER400 trailer error bits: "IDLE DATA" 
- result: INFO: CalDel:      135   134   126   121   158   141   119   133 _ 124 _ 107 _ 126 _ 108   133    91   138   120 
ROC8-ROC11 no hits! |  
| 
  190  
 | 
Mon Apr  6 17:18:02 2020 | 
Andrey Starodumov | Full test | FT of M1606, M1630, M1655, M1566 |  M1606: B due to mean noise of several ROCs> 200e 
M1639: C* due to failure many pixels of ROC1 at +10C as before: to be run at +10C with CtrlReg=17 
M1655: B due to mean noise of several ROCs> 200e 
M1656: B due to mean noise of several ROCs> 200e |  
| 
  189  
 | 
Mon Apr  6 17:07:23 2020 | 
Andrey Starodumov | HDI test | 8 HDIs tested |  HDIs 
4937 5043 5042 4040 
2029 4019 4018 4017 
are tested. All OK. |  
 
 |