Tue Apr 7 14:26:48 2020, Andrey Starodumov, Reception test, RT of M1567 failed
|
After exchange of TBM1 the results is the same:
[B]WAS[/B]:
|
Mon Apr 6 17:18:02 2020, Andrey Starodumov, Full test, FT of M1606, M1630, M1655, M1566
|
M1606: B due to mean noise of several ROCs> 200e
M1639: C* due to failure many pixels of ROC1 at +10C as before: to be run at +10C with CtrlReg=17
M1655: B due to mean noise of several ROCs> 200e
|
Mon Apr 6 17:07:23 2020, Andrey Starodumov, HDI test, 8 HDIs tested
|
HDIs
4937 5043 5042 4040
2029 4019 4018 4017
|
Mon Apr 6 14:52:09 2020, Andrey Starodumov, Reception test, RT of M1657 failed
|
No hits in ROC14 and ROC15.
Here is an error:
"ERROR: <datapipe.cc/CheckEventValidity:L524> Channel 5 Number of ROCs (1) != Token Chain Length (2)"
|
Mon Apr 6 14:42:43 2020, Andrey Starodumov, Reception test, RT of M1575 failed
|
Silvan has substituted the TBM0 of M1575.
Still no hits in ROC0-ROC3: "NO DATA" "IDLE DATA" warnings
The long cable has been attached.
|
Mon Apr 6 14:27:31 2020, Andrey Starodumov, Reception test, M1593
|
Silvan has substituted the TBM0 of M1593.
I had to substitute a cable that has residuals and with which the Reception test failed completely.
The long cable has been attached.
|
Thu Apr 2 22:50:33 2020, Andrey Starodumov, Full test, FT of M1645, M1646, M1647, M1648
|
All modules graded B due to mean noise > 200 electrons. |
Fri Apr 3 15:33:10 2020, Andrey Starodumov, Full test, FT of M1645, M1646, M1647, M1648
|
[quote="Andrey Starodumov"]All modules graded B due to mean noise > 200 electrons.[/quote]
Correction:
in reality M1546 has been tested and NOT 1646. M1646 failed Reception due to not working ROC and graded C.
|
Mon Apr 6 14:23:03 2020, Andrey Starodumov, Full test, FT of M1645, M1646, M1647, M1648
|
[quote="Andrey Starodumov"][quote="Andrey Starodumov"]All modules graded B due to mean noise > 200 electrons.[/quote]
Correction:
in reality M1546 has been tested and NOT 1646. M1646 failed Reception due to not working ROC and graded C.
|
Fri Apr 3 18:06:11 2020, Andrey Starodumov, HDI test, 2 HDIs tested
|
HDIs 6018 and 6019 are passed tests. |
Fri Apr 3 17:39:19 2020, Andrey Starodumov, Module doctor, M1654
|
After a protection cap glued to M1654, I observed a few strongly bent wire bonds and probably some shorts on ROC8. One (VD+) of them is even detached (on
HDI side). Pads from 25/26 till 35 are affected.
Nevertheless the Reception test gave the same results as before the cap gluing: grade A.
|
Fri Apr 3 17:29:51 2020, Andrey Starodumov, Full test, FT of M1557, M1591, M1649, M1651
|
M1557: C due to 214 pixel threshold failure in ROC4 only at +10C (several previous FTs at +10C were graded B!)
M1591: B due to mean noise > 200electrons for several ROCs
M1649: C due to 270 pixel threshold failure in ROC11 only at +10C
|
Thu Mar 26 17:45:15 2020, Andrey Starodumov, Full test, FT of M1545, M1557, M1627, M1628
|
Retested M1545: C->B (to be correct on the MoreWeb summary page)
Retested 1557: C->C in one ROC >160 pixels failed to be trimmed [B]Module placed in a tray C*[/B]
1627: B
|
Fri Apr 3 15:21:54 2020, Andrey Starodumov, Full test, FT of M1545, M1557, M1627, M1628
|
[quote="Andrey Starodumov"]Retested M1545: C->B (to be correct on the MoreWeb summary page)
Retested 1557: C->C in one ROC >160 pixels failed to be trimmed [B]Module placed in a tray C*[/B]
1627: B
|
Fri Apr 3 14:18:15 2020, Andrey Starodumov, Reception test, RT of M1651 on April 2
|
Due to damaged module adapter the first Reception test failed and after MoreWeb analysis graded C.
After second Reception test (with proper connected cable) the grade is A.
To keep grade A instead of C in the MoreWeb summary table I removed the directory of the first Reception:
|
Tue Mar 31 18:23:18 2020, Andrey Starodumov, Full test, FT of M1637, M1638, M1639, M1640
|
M1637: C. Graded C due to not completed first test at -20C. Urs has reported issues. The second -20C after T-Cycle and test at +10C are graded A.
Tomorrow I'll upgrade this module manually to A
M1638: A
|
Fri Apr 3 14:15:01 2020, Andrey Starodumov, Full test, FT of M1637, M1638, M1639, M1640
|
[quote="Andrey Starodumov"]M1637: C. Graded C due to not completed first test at -20C. Urs has reported issues. The second -20C after T-Cycle and test at
+10C are graded A.
Tomorrow I'll upgrade this module manually to A
|
Fri Apr 3 13:55:48 2020, Andrey Starodumov, Reception test, M1653 failed Reception
|
Roc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor! |
Thu Apr 2 17:10:08 2020, Andrey Starodumov, Other, Cap glued to M1618
|
M1618 has been tested (FT ) on March 23 without a protection cap.
I have no idea how it's happened...
Today cap is glued and module passed Reception test again and it's A.
|
Thu Apr 2 17:08:03 2020, Andrey Starodumov, HDI test, 6 HDIs tested
|
3013, 1046, 1047, 1048, 5038, 5039 are tested. All are OK. |
Thu Apr 2 17:06:19 2020, Andrey Starodumov, Reception test, M1652 failed Reception
|
ROC1 of M1652 is not programmable.
Put in the "Bad" tray as C module. |
Wed Apr 1 17:10:16 2020, Andrey Starodumov, Full test, FT of M1641-M1644
|
M1641: B due to mean noise > 200electons for a few ROCs
M1642: B due to mean noise > 200electons for a few ROCs
M1643: B due to mean noise > 200electons for a few ROCs
|
Tue Mar 31 17:33:37 2020, Andrey Starodumov, Reception test, RT of M1546
|
This is a module with a broken TBM. Silvan put a new one on top of the broken TBM.
The module is graded A after reception test.
I'm still not sure that wire-bonds of the new TBM is lower than capacitors. I'll try to glue a cap tomorrow
|
Wed Apr 1 15:32:43 2020, Andrey Starodumov, Reception test, RT of M1546
|
[quote="Andrey Starodumov"]This is a module with a broken TBM. Silvan put a new one on top of the broken TBM.
The module is graded A after reception test.
I'm still not sure that wire-bonds of the new TBM is lower than capacitors. I'll try to glue a cap tomorrow
|
Wed Apr 1 14:36:37 2020, Andrey Starodumov, Reception test, M1646 failed Reception
|
M1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery (between bonding pads) of ROC6.
To module doctor! |