CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 9 of 16  Not logged in ELOG logo
ID Date Authordown Category Subject Text Attachments
  115   Wed Mar 18 17:46:07 2020 Andrey StarodumovFull testFT of M1601-M1604M1601-M1604 passed full test
M1601: grade B
M1602-M1604: Grade C. The main reason is
  
  116   Thu Mar 19 17:17:27 2020 Andrey StarodumovReception testM1609-M16012Reception test done and caps are glued to
modules M1609-M1612.
M1611 graded B due to double column failure
  
  117   Thu Mar 19 18:01:50 2020 Andrey StarodumovFull testFT of M1605-M1608Only M1607 graded B. All others are graded
C due to trimbit test. 
M1606 should be looked carefully and may
  
  118   Fri Mar 20 14:46:31 2020 Andrey StarodumovReception testM1615 failedM1615 is programmable but "no working phases
found"
Visual inspection of wire bonds - OK.
  
  119   Fri Mar 20 14:53:52 2020 Andrey StarodumovReception testM1616 failedROC10 of M1616 is not programmable, no readout
from ROC10 and ROC11.
Visual inspection of wire bonds - OK
  
  120   Fri Mar 20 17:05:58 2020 Andrey StarodumovReception testM1617 failedROC8 of M1617 is programmable but no readout
from it.
Silvan noticed that a corner of one ROC of
  
  121   Fri Mar 20 18:09:47 2020 Andrey StarodumovHDI test3 HDIs tested5008 failed, but most likely die to the pin
head mis-alignment. Test to be repeated.
5007 and 5008: passed tests but during HV
  
  122   Fri Mar 20 18:32:34 2020 Andrey StarodumovFull testFT of M1609-M1612M1609 and M1611 are graded C
M1610 and M1612 are graded B
  
  126   Tue Mar 24 15:16:56 2020 Andrey StarodumovHDI test8 HDIs tested on Mar 231014, 1016, 2001, 2003, 
2004, 4013, 4015, 5014
All are good.
  
  127   Tue Mar 24 15:18:59 2020 Andrey StarodumovReception testM1621 failed ReceptionOn M1621 ROC8 is not programmable.   
  128   Tue Mar 24 15:20:18 2020 Andrey StarodumovReception testM1623 failed ReceptionM1623: all ROCs are programmable but no readout
from ROC0-ROC3.
Visual inspection is OK.
  
  129   Tue Mar 24 15:41:29 2020 Andrey StarodumovModule gradingChange in MoreWeb GradingParameters.cfg On March 3d the Vcal calibration parameter
has been changed:  
- StandardVcal2ElectronConversionFactor from
  
  130   Tue Mar 24 16:08:58 2020 Andrey StarodumovReception testM1625 failed ReceptionM1625: all ROCs are programmable but no readout
from ROC0-ROC3.
The same symptom as for M1623.
  
  131   Tue Mar 24 18:09:07 2020 Andrey StarodumovFull testFT of M1615, M1619, M1620, M1622Test results have been analysed with modified
code:
M1615: B
  
  132   Tue Mar 24 18:11:52 2020 Andrey StarodumovRe-gradingReanalised test resultsTest resulsts of several modules have been
re-analised without grading on trimbit failure.
  
  133   Wed Mar 25 14:11:35 2020 Andrey StarodumovReception testRT of M1613 and M1614 on Mar 20Reception test for these modules have been
done on Mar20.
Grading A for both modules.
  
  134   Wed Mar 25 14:17:51 2020 Andrey StarodumovFull testFT of M1609, M1613, M1614, M1618 on Mar 23FT for these modules has been done on Mar
23
M1609: C
  
  136   Wed Mar 25 14:44:37 2020 Andrey StarodumovReception testRT of M1627 and M1628Both modules graded A.   
  137   Wed Mar 25 17:03:11 2020 Andrey StarodumovFull testFT of M1615, M1619, M1620, M1622[quote="Andrey Starodumov"]Test results have
been analysed with modified code:
M1615: B
  
  138   Wed Mar 25 18:30:23 2020 Andrey StarodumovHDI test4+2 HDI tested2 suspicious HDIs retested and found OK: 5006/5007
5013, 5016, 3017, 3019 are OK.
  
ELOG V3.1.3-7933898