ID |
Date |
Author |
Category |
Subject |
Text |
|
115
|
Wed Mar 18 17:46:07 2020 |
Andrey Starodumov | Full test | FT of M1601-M1604 | M1601-M1604 passed full test
M1601: grade B
M1602-M1604: Grade C. The main reason is |
|
116
|
Thu Mar 19 17:17:27 2020 |
Andrey Starodumov | Reception test | M1609-M16012 | Reception test done and caps are glued to
modules M1609-M1612.
M1611 graded B due to double column failure |
|
117
|
Thu Mar 19 18:01:50 2020 |
Andrey Starodumov | Full test | FT of M1605-M1608 | Only M1607 graded B. All others are graded
C due to trimbit test.
M1606 should be looked carefully and may |
|
118
|
Fri Mar 20 14:46:31 2020 |
Andrey Starodumov | Reception test | M1615 failed | M1615 is programmable but "no working phases
found"
Visual inspection of wire bonds - OK.
|
|
119
|
Fri Mar 20 14:53:52 2020 |
Andrey Starodumov | Reception test | M1616 failed | ROC10 of M1616 is not programmable, no readout
from ROC10 and ROC11.
Visual inspection of wire bonds - OK
|
|
120
|
Fri Mar 20 17:05:58 2020 |
Andrey Starodumov | Reception test | M1617 failed | ROC8 of M1617 is programmable but no readout
from it.
Silvan noticed that a corner of one ROC of |
|
121
|
Fri Mar 20 18:09:47 2020 |
Andrey Starodumov | HDI test | 3 HDIs tested | 5008 failed, but most likely die to the pin
head mis-alignment. Test to be repeated.
5007 and 5008: passed tests but during HV |
|
122
|
Fri Mar 20 18:32:34 2020 |
Andrey Starodumov | Full test | FT of M1609-M1612 | M1609 and M1611 are graded C
M1610 and M1612 are graded B
|
|
126
|
Tue Mar 24 15:16:56 2020 |
Andrey Starodumov | HDI test | 8 HDIs tested on Mar 23 | 1014, 1016, 2001, 2003,
2004, 4013, 4015, 5014
All are good. |
|
127
|
Tue Mar 24 15:18:59 2020 |
Andrey Starodumov | Reception test | M1621 failed Reception | On M1621 ROC8 is not programmable. |
|
128
|
Tue Mar 24 15:20:18 2020 |
Andrey Starodumov | Reception test | M1623 failed Reception | M1623: all ROCs are programmable but no readout
from ROC0-ROC3.
Visual inspection is OK.
|
|
129
|
Tue Mar 24 15:41:29 2020 |
Andrey Starodumov | Module grading | Change in MoreWeb GradingParameters.cfg | On March 3d the Vcal calibration parameter
has been changed:
- StandardVcal2ElectronConversionFactor from |
|
130
|
Tue Mar 24 16:08:58 2020 |
Andrey Starodumov | Reception test | M1625 failed Reception | M1625: all ROCs are programmable but no readout
from ROC0-ROC3.
The same symptom as for M1623.
|
|
131
|
Tue Mar 24 18:09:07 2020 |
Andrey Starodumov | Full test | FT of M1615, M1619, M1620, M1622 | Test results have been analysed with modified
code:
M1615: B
|
|
132
|
Tue Mar 24 18:11:52 2020 |
Andrey Starodumov | Re-grading | Reanalised test results | Test resulsts of several modules have been
re-analised without grading on trimbit failure.
|
|
133
|
Wed Mar 25 14:11:35 2020 |
Andrey Starodumov | Reception test | RT of M1613 and M1614 on Mar 20 | Reception test for these modules have been
done on Mar20.
Grading A for both modules. |
|
134
|
Wed Mar 25 14:17:51 2020 |
Andrey Starodumov | Full test | FT of M1609, M1613, M1614, M1618 on Mar 23 | FT for these modules has been done on Mar
23
M1609: C
|
|
136
|
Wed Mar 25 14:44:37 2020 |
Andrey Starodumov | Reception test | RT of M1627 and M1628 | Both modules graded A. |
|
137
|
Wed Mar 25 17:03:11 2020 |
Andrey Starodumov | Full test | FT of M1615, M1619, M1620, M1622 | [quote="Andrey Starodumov"]Test results have
been analysed with modified code:
M1615: B
|
|
138
|
Wed Mar 25 18:30:23 2020 |
Andrey Starodumov | HDI test | 4+2 HDI tested | 2 suspicious HDIs retested and found OK: 5006/5007
5013, 5016, 3017, 3019 are OK. |
|