| ID | 
Date | 
Author  | 
Category | 
Subject | 
Text | 
  | 
| 
  115  
 | 
Wed Mar 18 17:46:07 2020 | 
Andrey Starodumov | Full test | FT of M1601-M1604 | M1601-M1604 passed full test
 
M1601: grade B
 
M1602-M1604: Grade C. The main reason is | 
   | 
| 
  116  
 | 
Thu Mar 19 17:17:27 2020 | 
Andrey Starodumov | Reception test | M1609-M16012 | Reception test done and caps are glued to 
modules M1609-M1612.
 
M1611 graded B due to double column failure | 
   | 
| 
  117  
 | 
Thu Mar 19 18:01:50 2020 | 
Andrey Starodumov | Full test | FT of M1605-M1608 | Only M1607 graded B. All others are graded 
C due to trimbit test. 
 
M1606 should be looked carefully and may | 
   | 
| 
  118  
 | 
Fri Mar 20 14:46:31 2020 | 
Andrey Starodumov | Reception test | M1615 failed | M1615 is programmable but "no working phases 
found"
 
Visual inspection of wire bonds - OK.
 | 
   | 
| 
  119  
 | 
Fri Mar 20 14:53:52 2020 | 
Andrey Starodumov | Reception test | M1616 failed | ROC10 of M1616 is not programmable, no readout 
from ROC10 and ROC11.
 
Visual inspection of wire bonds - OK
 | 
   | 
| 
  120  
 | 
Fri Mar 20 17:05:58 2020 | 
Andrey Starodumov | Reception test | M1617 failed | ROC8 of M1617 is programmable but no readout 
from it.
 
Silvan noticed that a corner of one ROC of | 
   | 
| 
  121  
 | 
Fri Mar 20 18:09:47 2020 | 
Andrey Starodumov | HDI test | 3 HDIs tested | 5008 failed, but most likely die to the pin 
head mis-alignment. Test to be repeated.
 
5007 and 5008: passed tests but during HV | 
   | 
| 
  122  
 | 
Fri Mar 20 18:32:34 2020 | 
Andrey Starodumov | Full test | FT of M1609-M1612 | M1609 and M1611 are graded C
 
M1610 and M1612 are graded B
 
 | 
   | 
| 
  126  
 | 
Tue Mar 24 15:16:56 2020 | 
Andrey Starodumov | HDI test | 8 HDIs tested on Mar 23 | 1014, 1016, 2001, 2003, 
 
2004, 4013, 4015, 5014
 
All are good. | 
   | 
| 
  127  
 | 
Tue Mar 24 15:18:59 2020 | 
Andrey Starodumov | Reception test | M1621 failed Reception | On M1621 ROC8 is not programmable. | 
   | 
| 
  128  
 | 
Tue Mar 24 15:20:18 2020 | 
Andrey Starodumov | Reception test | M1623 failed Reception | M1623: all ROCs are programmable but no readout 
from ROC0-ROC3.
 
Visual inspection is OK.
 | 
   | 
| 
  129  
 | 
Tue Mar 24 15:41:29 2020 | 
Andrey Starodumov | Module grading | Change in MoreWeb  GradingParameters.cfg  | On March 3d the Vcal calibration parameter 
has been changed:  
 
- StandardVcal2ElectronConversionFactor from | 
   | 
| 
  130  
 | 
Tue Mar 24 16:08:58 2020 | 
Andrey Starodumov | Reception test | M1625 failed Reception | M1625: all ROCs are programmable but no readout 
from ROC0-ROC3.
 
The same symptom as for M1623.
 | 
   | 
| 
  131  
 | 
Tue Mar 24 18:09:07 2020 | 
Andrey Starodumov | Full test | FT of M1615, M1619, M1620, M1622 | Test results have been analysed with modified 
code:
 
M1615: B
 | 
   | 
| 
  132  
 | 
Tue Mar 24 18:11:52 2020 | 
Andrey Starodumov | Re-grading | Reanalised test results | Test resulsts of several modules have been 
re-analised without grading on trimbit failure. 
 | 
   | 
| 
  133  
 | 
Wed Mar 25 14:11:35 2020 | 
Andrey Starodumov | Reception test | RT of M1613 and M1614 on Mar 20 | Reception test for these modules have been 
done on Mar20.
 
Grading A for both modules. | 
   | 
| 
  134  
 | 
Wed Mar 25 14:17:51 2020 | 
Andrey Starodumov | Full test | FT of M1609, M1613, M1614, M1618 on Mar 23 | FT for these modules has been done on Mar 
23
 
M1609: C
 | 
   | 
| 
  136  
 | 
Wed Mar 25 14:44:37 2020 | 
Andrey Starodumov | Reception test | RT of M1627 and M1628 | Both modules graded A. | 
   | 
| 
  137  
 | 
Wed Mar 25 17:03:11 2020 | 
Andrey Starodumov | Full test | FT of M1615, M1619, M1620, M1622 | [quote="Andrey Starodumov"]Test results have 
been analysed with modified code:
 
M1615: B
 | 
   | 
| 
  138  
 | 
Wed Mar 25 18:30:23 2020 | 
Andrey Starodumov | HDI test | 4+2 HDI tested | 2 suspicious HDIs retested and found OK: 5006/5007
 
5013, 5016, 3017, 3019 are OK. | 
   |