CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 7 of 16  Not logged in ELOG logo
ID Date Author Category Subject Text Attachments
  188   Mon Apr 6 14:52:09 2020 Andrey StarodumovReception testRT of M1657 failedNo hits in ROC14 and ROC15.
Here is an error:
"ERROR: <datapipe.cc/CheckEventValidity:L524>
  
  187   Mon Apr 6 14:42:43 2020 Andrey StarodumovReception testRT of M1575 failedSilvan has substituted the TBM0 of M1575.
Still no hits in ROC0-ROC3: "NO DATA" "IDLE
DATA" warnings
  
  186   Mon Apr 6 14:27:31 2020 Andrey StarodumovReception testM1593Silvan has substituted the TBM0 of M1593.
I had to substitute a cable that has residuals
and with which the Reception test failed
  
  185   Mon Apr 6 14:23:03 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"][quote="Andrey
Starodumov"]All modules graded B due to mean
noise > 200 electrons.[/quote]
  
  184   Fri Apr 3 18:06:11 2020 Andrey StarodumovHDI test2 HDIs testedHDIs 6018 and 6019 are passed tests.   
  183   Fri Apr 3 17:39:19 2020 Andrey StarodumovModule doctorM1654After a protection cap glued to M1654, I observed
a few strongly bent wire bonds and probably
some shorts on ROC8. One (VD+) of them is
  
  182   Fri Apr 3 17:29:51 2020 Andrey StarodumovFull testFT of M1557, M1591, M1649, M1651M1557: C due to 214 pixel threshold failure
in ROC4 only at +10C (several previous FTs
at +10C were graded B!)
  
  181   Fri Apr 3 15:33:10 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"]All modules graded
B due to mean noise > 200 electrons.[/quote]
Correction:
  
  180   Fri Apr 3 15:21:54 2020 Andrey StarodumovFull testFT of M1545, M1557, M1627, M1628[quote="Andrey Starodumov"]Retested M1545:
C->B (to be correct on the MoreWeb summary
page)
  
  179   Fri Apr 3 14:18:15 2020 Andrey StarodumovReception testRT of M1651 on April 2Due to damaged module adapter the first Reception
test failed and after MoreWeb analysis graded
C.
  
  178   Fri Apr 3 14:15:01 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640[quote="Andrey Starodumov"]M1637: C. Graded
C due to not completed first test at -20C.
Urs has reported issues. The second -20C
  
  177   Fri Apr 3 13:55:48 2020 Andrey StarodumovReception testM1653 failed ReceptionRoc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor!
  
  176   Thu Apr 2 22:50:33 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648All modules graded B due to mean noise > 200
electrons.
  
  175   Thu Apr 2 17:10:08 2020 Andrey StarodumovOtherCap glued to M1618M1618 has been tested (FT ) on March 23 without
a protection cap. 
I have no idea how it's happened...
  
  174   Thu Apr 2 17:08:03 2020 Andrey StarodumovHDI test6 HDIs tested3013, 1046, 1047, 1048, 5038, 5039 are tested.
All are OK.
  
  173   Thu Apr 2 17:06:19 2020 Andrey StarodumovReception testM1652 failed ReceptionROC1 of M1652 is not programmable. 
Put in the "Bad" tray as C module.
  
  172   Wed Apr 1 17:10:16 2020 Andrey StarodumovFull testFT of M1641-M1644M1641: B due to mean noise > 200electons for
a few ROCs
M1642: B due to mean noise > 200electons
  
  171   Wed Apr 1 15:32:43 2020 Andrey StarodumovReception testRT of M1546[quote="Andrey Starodumov"]This is a module
with a broken TBM. Silvan put a new one on
top of the broken TBM.
  
  170   Wed Apr 1 14:36:37 2020 Andrey StarodumovReception testM1646 failed ReceptionM1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery
(between bonding pads) of ROC6.
  
  169   Tue Mar 31 18:23:18 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640M1637: C. Graded C due to not completed first
test at -20C. Urs has reported issues. The
second -20C after T-Cycle and test at +10C
  
ELOG V3.1.3-7933898