CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 2 of 16  Not logged in ELOG logo
ID Date Author Category Subject Text Attachments
  289   Tue Jun 16 00:45:48 2020 Dinko FerencekFTs for ETHZModule list 3The following FullQualification tar file have
been uploaded to CERNBox
  
  288   Mon Jun 15 10:36:45 2020 Andrey StarodumovFTs for ETHZModule list 3M1596 2020-04-28 
M1597 2020-04-30 
M1598 2020-05-04 
  
  287   Tue Jun 9 17:19:00 2020 danek kotlinskiModule transfergel-pack transfers The following modules, which were already
X-ray tested and came back from ETHZ, 
have been transferred to gel_packs:
  
  286   Fri Jun 5 16:22:19 2020 Andrey StarodumovGeneralCleaning L1_DATA directoryTo be able to analyse Xray data and keep Total
Production overview in a proper state we
need to clean L1_DATA directory.
  
  285   Fri Jun 5 13:47:11 2020 Andrey StarodumovModule gradingM1613FT of this modules has been done twice: March
23 and March 25, in both cases with the final
test SW. On March 23 module was graded C
  
  284   Thu Jun 4 15:32:50 2020 Andrey StarodumovModule transfer18 Modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
T=+24C
  
  283   Thu Jun 4 11:32:46 2020 Dinko FerencekFTs for ETHZModule list2The following FullQualification tar file have
been uploaded to CERNBox
  
  281   Fri May 29 15:56:27 2020 Andrey StarodumovFTs for ETHZModule list2[COLOR=green]green:[/COLOR] correct in Total
production overview
black: to remove old entries/rows
  
  280   Fri May 29 15:41:40 2020 Andrey StarodumovGeneralM1546ROC10 of M1546 has 107 pixels with trimming
problems:
in a VCal threshold scan after trimming 81
 C10-p10.pdfTrimBits.pdfC10-50.pdf 
  279   Fri May 29 15:04:04 2020 Andrey StarodumovXRay HR testsAnalysis of HRT: M1555-M1561 and M1564Module            HRtest                VCal
calibration     Grade
          #defects        max #noisy pix
  
  278   Fri May 29 13:56:35 2020 Andrey StarodumovRe-gradingM1630In ROC1 of M1630 gain calibration failed massively
(3883 pixels) at +10C with CtrlReg 9.
A special test of M1630 only at +10C and
  
  277   Thu May 28 14:40:57 2020 Andrey StarodumovModule transfer8 modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
Module Current@-150V Programmable Readout
  
  276   Thu May 28 14:38:43 2020 Andrey StarodumovModule transfer18 Modules shipped to ETHZ1536, 1537, 1539, 1540, 1541,
1543, 1545, 1547, 1548, 1550,
1551, 1552, 1553, 1554, 1565,
  
  275   Tue May 26 23:00:50 2020 Dinko FerencekOtherProblem with external disk filling up too quicklyThe external hard disk (LaCie) used to back
up the L1 replacement data completely filled
up after transferring ~70 GB worth of data
  
  274   Tue May 26 22:56:46 2020 Dinko FerencekFTs for ETHZModule list1The following FullQualification tar file have
been uploaded to CERNBox
  
  273   Mon May 25 17:24:05 2020 Andrey StarodumovSoftwareChange in MoreWeb ColumnUniformityPerColumn.pyIn file
~/L1_SW/MoReWeb/Analyse/TestResultClasses/CMSPixel/QualificationGroup/XRayHRQualification$
emacs Chips/Chip/ColumnUniformityPerColumn/ColumnUniformityPerColumn.py
  
  272   Mon May 25 16:58:23 2020 Andrey StarodumovXRay HR testsa few commmentsThese is just to record the information:
1. measured hit rates at which Efficiency
and Xray hits Maps are taken are 40-50% of
  
  271   Fri May 22 17:09:37 2020 Andrey StarodumovFTs for ETHZModule list1[COLOR=green]green[/COLOR]: correct in Total
production overview
black: to remove old entries/raws
  
  270   Fri May 22 16:19:01 2020 Andrey StarodumovSoftwareChange in MoreWeb GradingParameters.cfgXray noise:
grade B moved from 300e to 400e
grade C moved from 400e to 500e
  
  269   Fri May 22 16:06:43 2020 Andrey StarodumovXRay HR testsAnalysis of HRT: M1623, M1632, M1634, M1636-M1639,M1640Module                HRtest             
  VCal calibration     Grade
           #defects      max #noisy pix
  
ELOG V3.1.3-7933898