CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 13 of 16  Not logged in ELOG logo
ID Date Author Categorydown Subject Text Attachments
  163   Tue Mar 31 09:29:02 2020 Urs LangeneggerFull testexchanged adapter for DTB_WXC03AI did not manage to get any r/o from the module
connected to that adapter, also after exchanging
the module.
  
  164   Tue Mar 31 10:32:32 2020 Urs LangeneggerFull testM1637Maybe M1637 has an issue: It got stuck twice
at the same place with 
  
  167   Tue Mar 31 17:36:36 2020 Urs LangeneggerFull testexchanged adapter for DTB_WXC03A[quote="Urs Langenegger"]I did not manage
to get any r/o from the module connected
to that adapter, also after exchanging the
  
  169   Tue Mar 31 18:23:18 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640M1637: C. Graded C due to not completed first
test at -20C. Urs has reported issues. The
second -20C after T-Cycle and test at +10C
  
  172   Wed Apr 1 17:10:16 2020 Andrey StarodumovFull testFT of M1641-M1644M1641: B due to mean noise > 200electons for
a few ROCs
M1642: B due to mean noise > 200electons
  
  176   Thu Apr 2 22:50:33 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648All modules graded B due to mean noise > 200
electrons.
  
  178   Fri Apr 3 14:15:01 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640[quote="Andrey Starodumov"]M1637: C. Graded
C due to not completed first test at -20C.
Urs has reported issues. The second -20C
  
  180   Fri Apr 3 15:21:54 2020 Andrey StarodumovFull testFT of M1545, M1557, M1627, M1628[quote="Andrey Starodumov"]Retested M1545:
C->B (to be correct on the MoreWeb summary
page)
  
  181   Fri Apr 3 15:33:10 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"]All modules graded
B due to mean noise > 200 electrons.[/quote]
Correction:
  
  182   Fri Apr 3 17:29:51 2020 Andrey StarodumovFull testFT of M1557, M1591, M1649, M1651M1557: C due to 214 pixel threshold failure
in ROC4 only at +10C (several previous FTs
at +10C were graded B!)
  
  185   Mon Apr 6 14:23:03 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"][quote="Andrey
Starodumov"]All modules graded B due to mean
noise > 200 electrons.[/quote]
  
  190   Mon Apr 6 17:18:02 2020 Andrey StarodumovFull testFT of M1606, M1630, M1655, M1566M1606: B due to mean noise of several ROCs>
200e
M1639: C* due to failure many pixels of ROC1
  
  193   Tue Apr 7 16:57:01 2020 Andrey StarodumovFull testFT of M1593, M1658, M1659, M1660M1593: B due to Rel.gain width and mean noise
of a few ROCs
M1658: B due to threshold and mean noise
  
  200   Wed Apr 8 17:09:05 2020 Andrey StarodumovFull testFT of M1572, M1661, M1663, M1664M1572: Grade B due to mean noise of ROC4 211
electrons
M1661: Grade B due to mean noise of a few
  
  206   Thu Apr 9 17:24:49 2020 Andrey StarodumovFull testFT of M1654, M1665, M1666, M1667M1654: Grade A
M1665: Grade B due to noisy pixels in ROC5.
To be checked by module doctor!
  
  211   Tue Apr 14 17:19:44 2020 Andrey StarodumovFull testFT of M1668, M1669, M1670, M1672M1668: Grade B due to mean noise >200e for
several ROCs
M1669: Grade B due to ROC2 mean noise >200e
  
  215   Wed Apr 15 17:26:46 2020 Andrey StarodumovFull testFT of M1623, M1657, M1673, M1674M1623: Grade B due to rel gain width, in ROC4
74 pixels failed trimming (Threshold) and
mean noise >200e
  
  218   Thu Apr 16 17:31:16 2020 Andrey StarodumovFull testFT of M1662, M1675, M1676M1662: Grade C due to failure of ROC4 in almost
all tests: PixelAlive, PH calibration etc
Should be investigated and retested. At Reception
  
  219   Fri Apr 17 18:05:45 2020 Andrey StarodumovFull testFT of M1542, M1557, M1630, M1649 only at +10CM1542 has grade C for relative gain width.
Was tested with early versions of test SW
with trim VCal=40 and not yet optimized PH
  
  223   Tue Apr 21 17:39:48 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653M1542: Grade C due to massive (>1000pixels
in total) trimming failures at -20C in ROC11,14,15.
There was no such problem at previous test
  
ELOG V3.1.3-7933898