| ID | 
Date | 
Author  | 
Category | 
Subject | 
Text | 
  | 
| 
  235  
 | 
Tue Apr 28 18:06:41 2020 | 
Andrey Starodumov | Full test | FT of M1582, M1583, M1584, M1585 | Modules tested om Apr 27
 
M1582: Grade C due to 167 pixels failed trimming 
on ROC1 at +10C only. Previous test on Feb | 
   | 
| 
  236  
 | 
Tue Apr 28 18:11:45 2020 | 
Andrey Starodumov | Full test | FT of M1586, M1587, M1588, M1589 | M1586: Grade B due to mean noise >200e for 
a few ROCs
 
M1587: Grade B due to mean noise >200e for | 
   | 
| 
  238  
 | 
Wed Apr 29 14:08:42 2020 | 
Andrey Starodumov | Full test | FT of M1536, M1537, M1538 | M1536: Grade B due to mean noise >200e for 
ROC1
 
M1537: Grade B due to mean noise >200e for | 
   | 
| 
  239  
 | 
Wed Apr 29 18:11:36 2020 | 
Andrey Starodumov | Full test | FT of M1590, M1592, M1596, M1600 | Modules tested om April 28
 
M1590: Grade B  Grade B due to mean noise 
>200e for a few ROCs
 | 
   | 
| 
  240  
 | 
Thu Apr 30 15:16:58 2020 | 
Andrey Starodumov | Full test | FT of M1540, M1541, M1543, M1547 | Modules tested om April 29
 
M1540: Grade B due to many (>1000) pixels 
failed trimming but only 70 are in "C-zone" | 
   | 
| 
  241  
 | 
Thu Apr 30 15:25:36 2020 | 
Andrey Starodumov | Full test | FT of M1548, M1549, M1550, M1551 | M1548: Grade B due to mean noise >200e for 
ROC11
 
M1549: Grade B due to mean noise >200e for | 
   | 
| 
  245  
 | 
Thu Apr 30 17:33:04 2020 | 
Andrey Starodumov | Software | MoReWeb empty DAC plots | [quote="Matej Roguljic"]Some of the DAC parameters 
plots were empty in the total production 
overview page. All the empty plots had the | 
   | 
| 
  247  
 | 
Mon May  4 14:13:39 2020 | 
Andrey Starodumov | Full test | FT of M1552, M1553, M1595, M1597 | FT on April 30th
 
M1552: Grade B due to mean noise >200e for 
ROC7,8
 | 
   | 
| 
  248  
 | 
Mon May  4 14:18:20 2020 | 
Andrey Starodumov | Full test | FT of M1540, 1549, 1571, 1598 | M1540: Grade A
 
M1549: Grade B due to mean noise >200e for 
ROC2 and 48 dead pixels in ROC5
 | 
   | 
| 
  249  
 | 
Mon May  4 15:28:14 2020 | 
Andrey Starodumov | General | M1660  | M1660 is taken from gel-pak and cabled for 
retest.
 
This module was graded C only at second FT | 
   | 
| 
  250  
 | 
Tue May  5 13:58:45 2020 | 
Andrey Starodumov | Full test | FT of M1582, M1649, M1667 | M1582: Grade C due to trimming failure in 
ROC1 for 189 pixels at +10C. This is third 
time module restesed:
 | 
   | 
| 
  251  
 | 
Wed May  6 13:20:28 2020 | 
Andrey Starodumov | Full test | FT of M1574, M1581, M1660, M1668 | Modules tested on May 5th
 
M1574: Grade B due to mean noise >200e in 
ROC10 and trimming failures for 89 pixels | 
   | 
| 
  252  
 | 
Wed May  6 16:24:21 2020 | 
Andrey Starodumov | Full test | FT of M1580, M1595, M1606, M1659 | M1580: Grade B due to mean noise >200e in 
ROC5/8 and trimming failures for 100+ pixels 
in the same ROCs at +10C, previous result | 
   | 
| 
  257  
 | 
Mon May 11 13:19:51 2020 | 
Andrey Starodumov | Cold box tests | M1539 | After several attempts including reconnecting 
the cable, M1539 had no readout if it's connected 
to TB3. When connected to TB1, M1539 did | 
   | 
| 
  263  
 | 
Tue May 12 13:29:27 2020 | 
Andrey Starodumov | Full test | FT of M1539, M1582, M1606 | M1539: Grade B due to mean noise >200e in 
few ROCs
 
M1582: Grade B due to mean noise >200e in | 
   | 
| 
  264  
 | 
Wed May 13 17:57:45 2020 | 
Andrey Starodumov | Other | L1_DATA backup | L1_DATA files are backed up to the LaCie disk | 
   | 
| 
  266  
 | 
Fri May 15 17:15:34 2020 | 
Andrey Starodumov | XRay HR tests | Analysis of HRT:  M1630, M1632, M1636, M1638 | Krunal proved test result of four modules 
and Dinko analised them.
 
M1630: Grade A, VCal calibration: Slope=43.5e-/Vcal, | 
   | 
| 
  267  
 | 
Mon May 18 14:05:01 2020 | 
Andrey Starodumov | Module transfer | 8 modules shipped to ETHZ | M1555, M1556, M1557, 
 
M1558, M1559, M1560,
 
M1561, M1564 | 
   | 
| 
  268  
 | 
Tue May 19 13:43:55 2020 | 
Andrey Starodumov | Module transfer | 9 modules shipped to PSI | Quick check: Leakage current, set Vana, VthrCompCalDel 
and PixelAlive
 
Module    Current@-150V    Programmable  | 
   | 
| 
  269  
 | 
Fri May 22 16:06:43 2020 | 
Andrey Starodumov | XRay HR tests | Analysis of HRT: M1623, M1632, M1634, M1636-M1639,M1640 | Module                HRtest              
  VCal calibration     Grade
 
           #defects      max #noisy pix
 | 
   |