CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 14 of 16  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Category Subject Text Attachments
  235   Tue Apr 28 18:06:41 2020 Andrey StarodumovFull testFT of M1582, M1583, M1584, M1585Modules tested om Apr 27
M1582: Grade C due to 167 pixels failed trimming
on ROC1 at +10C only. Previous test on Feb
  
  236   Tue Apr 28 18:11:45 2020 Andrey StarodumovFull testFT of M1586, M1587, M1588, M1589M1586: Grade B due to mean noise >200e for
a few ROCs
M1587: Grade B due to mean noise >200e for
  
  238   Wed Apr 29 14:08:42 2020 Andrey StarodumovFull testFT of M1536, M1537, M1538M1536: Grade B due to mean noise >200e for
ROC1
M1537: Grade B due to mean noise >200e for
  
  239   Wed Apr 29 18:11:36 2020 Andrey StarodumovFull testFT of M1590, M1592, M1596, M1600Modules tested om April 28
M1590: Grade B  Grade B due to mean noise
>200e for a few ROCs
  
  240   Thu Apr 30 15:16:58 2020 Andrey StarodumovFull testFT of M1540, M1541, M1543, M1547Modules tested om April 29
M1540: Grade B due to many (>1000) pixels
failed trimming but only 70 are in "C-zone"
  
  241   Thu Apr 30 15:25:36 2020 Andrey StarodumovFull testFT of M1548, M1549, M1550, M1551M1548: Grade B due to mean noise >200e for
ROC11
M1549: Grade B due to mean noise >200e for
  
  245   Thu Apr 30 17:33:04 2020 Andrey StarodumovSoftwareMoReWeb empty DAC plots[quote="Matej Roguljic"]Some of the DAC parameters
plots were empty in the total production
overview page. All the empty plots had the
  
  247   Mon May 4 14:13:39 2020 Andrey StarodumovFull testFT of M1552, M1553, M1595, M1597FT on April 30th
M1552: Grade B due to mean noise >200e for
ROC7,8
  
  248   Mon May 4 14:18:20 2020 Andrey StarodumovFull testFT of M1540, 1549, 1571, 1598M1540: Grade A
M1549: Grade B due to mean noise >200e for
ROC2 and 48 dead pixels in ROC5
  
  249   Mon May 4 15:28:14 2020 Andrey StarodumovGeneralM1660 M1660 is taken from gel-pak and cabled for
retest.
This module was graded C only at second FT
  
  250   Tue May 5 13:58:45 2020 Andrey StarodumovFull testFT of M1582, M1649, M1667M1582: Grade C due to trimming failure in
ROC1 for 189 pixels at +10C. This is third
time module restesed:
  
  251   Wed May 6 13:20:28 2020 Andrey StarodumovFull testFT of M1574, M1581, M1660, M1668Modules tested on May 5th
M1574: Grade B due to mean noise >200e in
ROC10 and trimming failures for 89 pixels
  
  252   Wed May 6 16:24:21 2020 Andrey StarodumovFull testFT of M1580, M1595, M1606, M1659M1580: Grade B due to mean noise >200e in
ROC5/8 and trimming failures for 100+ pixels
in the same ROCs at +10C, previous result
  
  257   Mon May 11 13:19:51 2020 Andrey StarodumovCold box testsM1539After several attempts including reconnecting
the cable, M1539 had no readout if it's connected
to TB3. When connected to TB1, M1539 did
  
  263   Tue May 12 13:29:27 2020 Andrey StarodumovFull testFT of M1539, M1582, M1606M1539: Grade B due to mean noise >200e in
few ROCs
M1582: Grade B due to mean noise >200e in
  
  264   Wed May 13 17:57:45 2020 Andrey StarodumovOtherL1_DATA backupL1_DATA files are backed up to the LaCie disk   
  266   Fri May 15 17:15:34 2020 Andrey StarodumovXRay HR testsAnalysis of HRT: M1630, M1632, M1636, M1638Krunal proved test result of four modules
and Dinko analised them.
M1630: Grade A, VCal calibration: Slope=43.5e-/Vcal,
  
  267   Mon May 18 14:05:01 2020 Andrey StarodumovModule transfer8 modules shipped to ETHZM1555, M1556, M1557, 
M1558, M1559, M1560,
M1561, M1564
  
  268   Tue May 19 13:43:55 2020 Andrey StarodumovModule transfer9 modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
Module    Current@-150V    Programmable 
  
  269   Fri May 22 16:06:43 2020 Andrey StarodumovXRay HR testsAnalysis of HRT: M1623, M1632, M1634, M1636-M1639,M1640Module                HRtest             
  VCal calibration     Grade
           #defects      max #noisy pix
  
ELOG V3.1.3-7933898