CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 15 of 16  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Category Subjectdown Text Attachments
  59   Mon Feb 3 15:35:09 2020 Anrey StarodumovFull test4 modules FT: 1539, 1541,1542, 1543[COLOR=blue]Jan 29[/COLOR] 
- Reception test for 1539 OK
- Cap gluing
 1542ROC13-TrThr.pdf 
  58   Mon Feb 3 11:28:38 2020 Anrey StarodumovFull test4 modules FT: 1536, 1537,1538, 1540[COLOR=blue]Jan 28[/COLOR]: Reception test
for 1536, 1537, 1538 OK
Then cap gluing
 1537ROC10m20-TrThr.pdf 
  43   Mon Dec 2 17:29:06 2019 Andrey StarodumovFull test4 modules FTFullQualification of four modules M1526, M1529,
M1521 and M1534 has been done. Full time
of the test is about 5.5hrs.
  
  44   Tue Dec 3 12:15:54 2019 Andrey StarodumovFull test4 modules FT[quote="Andrey Starodumov"]FullQualification
of four modules M1526, M1529, M1521 and M1534
has been done. Full time of the test is about
 M1526ATm20.pngM1526ATp10.png 
  153   Fri Mar 27 18:28:34 2020 Andrey StarodumovFull test4 HDIs testedHDIs 5020, 5018, 1044 and 1041 are OK   
  221   Mon Apr 20 17:09:12 2020 Andrey StarodumovHDI test4 HDIs testedAfter staying in 90%+ RH 2 HDIs became flat.
The first one was easy to mount on an HDI
holder.
  
  229   Thu Apr 23 18:01:16 2020 Andrey StarodumovHDI test4 HDIs testedThe following HDIs are tested:
6007: OK
1034: Failed due to not working Channel 1
  
  208   Thu Apr 9 17:43:54 2020 Andrey StarodumovHDI test4 HDIa testedHDIs 3029, 3031, 3032, 4042 passed tests.
All OK.
  
  159   Mon Mar 30 17:40:35 2020 Andrey StarodumovHDI test3+2 HDIs (re-)testedFor 3 HDIs: 3014, 3017, 6021, HV has been
re-measured. In all cases 790V is measured
with 800V supplied.
  
  121   Fri Mar 20 18:09:47 2020 Andrey StarodumovHDI test3 HDIs tested5008 failed, but most likely die to the pin
head mis-alignment. Test to be repeated.
5007 and 5008: passed tests but during HV
  
  230   Fri Apr 24 13:56:11 2020 Andrey StarodumovHDI test3 HDIs testedFollowing HDIs tested from the box "to be
understood":
5021, 3019, 5008. All are fine.
  
  234   Mon Apr 27 14:21:17 2020 Andrey StarodumovHDI test3 HDIs tested# remaining HDIs from "to be understood" box
were tested after flattening them during
weekend in RH=99.9% box.
  
  168   Tue Mar 31 18:14:47 2020 Andrey StarodumovHDI test3 HDI testedHDIs: 1027, 5002, 5003 are tested. All OK.   
  61   Mon Feb 3 17:09:36 2020 Andrey StarodumovReception test2 modules RT failed: 1544, 1546[COLOR=blue]Feb 03[/COLOR]
- RT failed
-- 1544: 
  
  184   Fri Apr 3 18:06:11 2020 Andrey StarodumovHDI test2 HDIs testedHDIs 6018 and 6019 are passed tests.   
  284   Thu Jun 4 15:32:50 2020 Andrey StarodumovModule transfer18 Modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
T=+24C
  
  276   Thu May 28 14:38:43 2020 Andrey StarodumovModule transfer18 Modules shipped to ETHZ1536, 1537, 1539, 1540, 1541,
1543, 1545, 1547, 1548, 1550,
1551, 1552, 1553, 1554, 1565,
  
  262   Mon May 11 21:41:15 2020 Dinko FerencekSoftware17 to 10 C changes in the production overview page[URL=https://gitlab.cern.ch/CMS-IRB/MoReWeb/-/commit/0c513ab8de39460ed793ef71c21b65becd4fccb9]0c513ab8[/URL]:
a few more updates on the main production
overview page related to the 17 to 10 C change
  
  224   Wed Apr 22 17:28:42 2020 Andrey StarodumovHDI test11 HDIs testedAfter keeping HDIs in a very high RH for a
dew hours (24 is fine) became flat and could
be fixed on HDI holder by vacuum.
  
  23   Mon Oct 28 17:01:05 2019 Matej RoguljicSoftware Investigating the bug with the Keithley clientWe took module 1529 and tried recreating the
issue observed in the beginning of October.
To do this in a reasonable amount of time,
  
ELOG V3.1.3-7933898