  152   Fri Mar 27 17:27:09 2020 Andrey StarodumovReception testM1635 failed ReceptionAll ROCs are programmable but DESER400 trailer
error bits: "NO DATA" or "IDLE DATA".
ROC8-11 are affected (no data)
  
  160   Mon Mar 30 17:49:31 2020 Andrey StarodumovReception testRT of M1637-1640All modules: M1637, M1638, M1639, M1649, are
graded A.
 
  
  165   Tue Mar 31 17:32:47 2020 Andrey StarodumovReception testRT of M1641-M1644All modules graded A.   
  166   Tue Mar 31 17:33:37 2020 Andrey StarodumovReception testRT of M1546This is a module with a broken TBM. Silvan
put a new one on top of the broken TBM.
The module is graded A after reception test.
  
  170   Wed Apr 1 14:36:37 2020 Andrey StarodumovReception testM1646 failed ReceptionM1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery
(between bonding pads) of ROC6.
  
  171   Wed Apr 1 15:32:43 2020 Andrey StarodumovReception testRT of M1546[quote="Andrey Starodumov"]This is a module
with a broken TBM. Silvan put a new one on
top of the broken TBM.
  
  173   Thu Apr 2 17:06:19 2020 Andrey StarodumovReception testM1652 failed ReceptionROC1 of M1652 is not programmable. 
Put in the "Bad" tray as C module.
  
  177   Fri Apr 3 13:55:48 2020 Andrey StarodumovReception testM1653 failed ReceptionRoc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor!
  
  179   Fri Apr 3 14:18:15 2020 Andrey StarodumovReception testRT of M1651 on April 2Due to damaged module adapter the first Reception
test failed and after MoreWeb analysis graded
C.
  
  186   Mon Apr 6 14:27:31 2020 Andrey StarodumovReception testM1593Silvan has substituted the TBM0 of M1593.
I had to substitute a cable that has residuals
and with which the Reception test failed
  
  187   Mon Apr 6 14:42:43 2020 Andrey StarodumovReception testRT of M1575 failedSilvan has substituted the TBM0 of M1575.
Still no hits in ROC0-ROC3: "NO DATA" "IDLE
DATA" warnings
  
  188   Mon Apr 6 14:52:09 2020 Andrey StarodumovReception testRT of M1657 failedNo hits in ROC14 and ROC15.
Here is an error:
"ERROR: <datapipe.cc/CheckEventValidity:L524>
  
  191   Tue Apr 7 14:26:48 2020 Andrey StarodumovReception testRT of M1567 failedAfter exchange of TBM1 the results is the
same:
  
  192   Tue Apr 7 15:25:21 2020 Andrey StarodumovReception testRT of M1662 failedAddress decoding of M1662 failed in one double
column of ROC4.
To be decided what to do with this module.
  
  195   Tue Apr 7 18:02:07 2020 Andrey StarodumovReception testRT of 1654After Silvan removed a cap and re-bonded broken
and bent wires M1654 again has been tested.
RT grade is A.
  
  196   Wed Apr 8 13:40:45 2020 Andrey StarodumovReception testRT of M1625 failedSilvan substituted TBM on this module.
Now ROC0 does not have hits.
Grade C, goes to "Bad" tray.
  
  197   Wed Apr 8 13:43:15 2020 Andrey StarodumovReception testRT of M1623 failedM1623: all ROCs are programmable but no readout
from ROC8-ROC11.
Visual inspection is OK.
  
  199   Wed Apr 8 15:20:38 2020 Andrey StarodumovReception testRT of M1665With CtrlReg=9 RT grade was B due to 90 noisy
pixels in ROC5.
Noisy in this case means that one pixel in
  
  201   Wed Apr 8 17:17:13 2020 Andrey StarodumovReception testRT of M1662 failed[quote="Andrey Starodumov"]Address decoding
of M1662 failed in one double column of ROC4.
To be decided what to do with this module.
  
  203   Thu Apr 9 14:36:10 2020 Andrey StarodumovReception testRT of M1669 and M1670Both modules graded A.   