CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 5 of 13  Not logged in ELOG logo
Entry  Wed Apr 15 08:48:09 2020, danek kotlinski, Module doctor, Wolfram's tests from 14/4/20 
two of are fixed and can be re-tested
M1623   tbm bond
M1657   bond roc 15
Entry  Tue Apr 14 17:29:46 2020, Andrey Starodumov, General, ROC4 or ROC12 defects 
Starting from M1650 almost every module has a cluster of dead pixels or broken bump bonds on
ROC4 or (more often) ROC12. The number of defects varied from 20 to 40.
It's almost excluded that such damage is made at PSI, since both of us: Silvan and me, first time connected the cable
Entry  Tue Apr 14 17:19:44 2020, Andrey Starodumov, Full test, FT of M1668, M1669, M1670, M1672 
M1668: Grade B due to mean noise >200e for several ROCs
M1669: Grade B due to ROC2 mean noise >200e
M1670: Grade B due to ROC1 mean noise >200e
Entry  Tue Apr 14 16:54:31 2020, Andrey Starodumov, Other, M1633 cable disconnected 
We do not have any more module holders. 
M1633 was in "Module doctor" tray.
I took module off the holder and put it in a gel-pak.
Entry  Tue Apr 14 15:49:05 2020, Andrey Starodumov, Reception test, RT of M1623, M1657, M1673, M1674 
M1623: Grade A, should be B due to 71 bump defects in ROC4 
M1657: Grade B, due to 51 dead pixels in ROC12
M1673: Grade A, again 31 dead bumps in ROC12
Entry  Thu Apr 9 17:43:54 2020, Andrey Starodumov, HDI test, 4 HDIa tested 
HDIs 3029, 3031, 3032, 4042 passed tests. All OK.
Entry  Thu Apr 9 17:36:31 2020, Andrey Starodumov, Reception test, RT of M1671 failed 
ROC12-ROC15 no hits.
A candidate to TBM0 substitution, hence Grade C*.
To Module doctor1
Entry  Thu Apr 9 17:24:49 2020, Andrey Starodumov, Full test, FT of M1654, M1665, M1666, M1667 
M1654: Grade A
M1665: Grade B due to noisy pixels in ROC5. To be checked by module doctor!
M1666: Grade B due to mean noise of several chips > 200 electrons. Again on ROC12 there is a cluster of 31 dead bumps!
Entry  Thu Apr 9 14:19:40 2020, danek kotlinski, Module transfer, Modules moved to gel-pack 
The following good module class A/B have been moved to gel-packs:
1607, 1608, 1609, 1610, 1612, 1613, 1614, 1618, 1619, 1620, 1622, 1624, 1626, 1627, 1628.
    Reply  Thu Apr 9 16:13:51 2020, danek kotlinski, Module transfer, Modules moved to gel-pack 
[quote="danek kotlinski"]The following good module class A/B have been moved to gel-packs:
1607, 1608, 1609, 1610, 1612, 1613, 1614, 1618, 1619, 1620, 1622, 1624, 1626, 1627, 1628.
Entry  Thu Apr 9 14:49:07 2020, Andrey Starodumov, Reception test, RT of M1650 failed 
Module has been tested on April 2nd.
Under Molex connector in ROC12 471 dead or noisy pixels.
Grade C.
Entry  Thu Apr 9 14:36:10 2020, Andrey Starodumov, Reception test, RT of M1669 and M1670 
Both modules graded A.
Entry  Tue Apr 7 15:25:21 2020, Andrey Starodumov, Reception test, RT of M1662 failed 
Address decoding of M1662 failed in one double column of ROC4.
To be decided what to do with this module.
Currently in C* tray.
    Reply  Wed Apr 8 17:17:13 2020, Andrey Starodumov, Reception test, RT of M1662 failed 
[quote="Andrey Starodumov"]Address decoding of M1662 failed in one double column of ROC4.
To be decided what to do with this module.
Currently in C* tray.[/quote]
Entry  Wed Apr 8 17:09:05 2020, Andrey Starodumov, Full test, FT of M1572, M1661, M1663, M1664 
M1572: Grade B due to mean noise of ROC4 211 electrons
M1661: Grade B due to mean noise of a few ROCs > 200 electrons and in ROC12 44 pixels failed threshold cut
M1663: Grade B due to mean noise of a few ROCs > 200 electrons
Entry  Wed Apr 8 15:20:38 2020, Andrey Starodumov, Reception test, RT of M1665 
With CtrlReg=9 RT grade was B due to 90 noisy pixels in ROC5.
Noisy in this case means that one pixel in a 2x2 cluster in a few column got 40 hits instead of 10.
With CtrlReg=17 this problem gone. RT grade is A.
Entry  Wed Apr 8 15:02:37 2020, Andrey Starodumov, Software, Change of CrtlReg for RT 
So far in a blue box for RT tbm10d_procv3 parameters were used. 
This is wrong, since CtrlReg=9 is better for -20C while for +10 or higher T
CtrlReg=17 is better. 
Entry  Wed Apr 8 13:43:15 2020, Andrey Starodumov, Reception test, RT of M1623 failed 
M1623: all ROCs are programmable but no readout from ROC8-ROC11.
Visual inspection is OK.
To module doctor. 
Entry  Wed Apr 8 13:40:45 2020, Andrey Starodumov, Reception test, RT of M1625 failed 
Silvan substituted TBM on this module.
Now ROC0 does not have hits.
Grade C, goes to "Bad" tray.
Entry  Tue Apr 7 18:02:07 2020, Andrey Starodumov, Reception test, RT of 1654 
After Silvan removed a cap and re-bonded broken and bent wires M1654 again has been tested.
RT grade is A.
Protection cap to be glued and to be (F)tested.
Entry  Tue Apr 7 17:59:27 2020, Andrey Starodumov, HDI test, 6 HDIs tested 
HDIs
2030, 2031, 1021, 1022, 1023, 1035 
are tested. All OK.
Entry  Tue Apr 7 16:57:01 2020, Andrey Starodumov, Full test, FT of M1593, M1658, M1659, M1660 
M1593: B due to Rel.gain width and mean noise of a few ROCs
M1658: B due to threshold and mean noise of ROC15
M1659: B due to threshold and mean noise of a few ROCs
ELOG V3.1.3-7933898