  309   Mon Jan 25 13:03:22 2021 Dinko FerencekPOSPOS configuration files createdThe output POS configuration files has '_Bpix_'
instead of '_BPix_' in their names. The culprit
was identified to be the C3 cell in the 'POS'
  
  4   Tue Aug 6 16:06:45 2019 Matej RoguljicOtherVsh and ctrlreg for v4 chipsThe recommended default value for Vsh is 8,
but the current version of pXar has it as
30. One should remember this when making
  
  8   Tue Sep 10 15:18:20 2019 Matej RoguljicOtherModules 1504, 1505, 1520 irradiation reportModules 1504, 1505 and 1520 were taken to
Zagreb for irradiation on 13.08.19. The goal
was to check the v4 behavior after irradiation.
  
  10   Fri Sep 13 15:06:51 2019 Andrey StarodumovOtherModules 1504, 1505, 1520 irradiation reportIt was discovered that these modules were
stored in Zagreb in the climatic lab where
T was about +22C. These modules have been
  
  12   Thu Sep 19 00:52:24 2019 Dinko FerencekOtherModules 1504, 1505, 1520 irradiation report[quote="Andrey Starodumov"]It was discovered
that these modules were stored in Zagreb
in the climatic lab where T was about +22C.
 ZG-FER_temp_hum_2019.08.16.-09.16.pngpixellab-main-room-1.png 
  99   Wed Mar 11 15:34:57 2020 Urs LangeneggerOtherM1586: issues with MOLEX?Module M1586 had passed the full qualification
on 20/02/27. I had had to re-insert the cable
in the Molex connector for it to become programmable.
  
  100   Wed Mar 11 16:48:10 2020 Andrey StarodumovOtherM1586: issues with MOLEX?[quote="Urs Langenegger"]Module M1586 had
passed the full qualification on 20/02/27.
I had had to re-insert the cable in the Molex
  
  155   Sun Mar 29 18:14:59 2020 danek kotlinskiOtherModules 1544 & 1563 in gelpackThe 2 bad modules:
M1544
M1563 
  
  175   Thu Apr 2 17:10:08 2020 Andrey StarodumovOtherCap glued to M1618M1618 has been tested (FT ) on March 23 without
a protection cap. 
I have no idea how it's happened...
  
  210   Tue Apr 14 16:54:31 2020 Andrey StarodumovOtherM1633 cable disconnectedWe do not have any more module holders. 
M1633 was in "Module doctor" tray.
I took module off the holder and put it in
  
  237   Wed Apr 29 08:48:06 2020 Urs LangeneggerOtherM1539M1539 showed no readout. I tried, all without
success, 
- reconnecting the cable to the adapter multiple
  
  258   Mon May 11 14:14:05 2020 danek kotlinskiOtherM1606On Friday I have tested M1606 at room temperature
in the red cold box.
Previously it was reported that trimming
 m1606_roc2_thr_1d.pngm1606_roc2_thr_2d.pngm1606_roc2_ph70.png 
  259   Mon May 11 14:40:16 2020 danek kotlinskiOtherM1582On Friday I have tested the module M1582 at
room temperature in the blue box.
The report in MoreWeb says that this module
 m1582_roc1_thr_1d.pngm1582_roc1_thr_2d.pngm1582_roc1_ph70.png 
  264   Wed May 13 17:57:45 2020 Andrey StarodumovOtherL1_DATA backupL1_DATA files are backed up to the LaCie disk   
  275   Tue May 26 23:00:50 2020 Dinko FerencekOtherProblem with external disk filling up too quicklyThe external hard disk (LaCie) used to back
up the L1 replacement data completely filled
up after transferring ~70 GB worth of data
  
  303   Fri Sep 18 15:45:21 2020 Andrey StarodumovOtherM2211 and M2122I made a mistake and instead M2122 used ID
M2211 in the .ini file.
Hence now we do not have entry for M2122
  
  307   Mon Jan 18 13:53:44 2021 Andrey StarodumovOtherDTB testsM2217
--->DTB 154 (one of the red cold box setup):
- flat cable (with HV):
  
  301   Wed Sep 2 16:09:24 2020 Matej RoguljicModules for PM1595 switch with M1558Module 1595 was foreseen to go on the inner
ladder 5, position -2 (negative two). During
the pre-installation test, we saw it had
  
  62   Tue Feb 4 19:35:38 2020 Dinko FerencekModule transfer7 modules prepared for transfer to ETH: 1536, 1537, 1538, 1540, 1541, 1542, 1543The following modules have been prepared today
for transport to ETH for x-ray qualification:
1536, 1537, 1538, 1540, 1541, 1542, 1543
  
  66   Wed Feb 5 16:18:30 2020 Dinko FerencekModule transferModule location tracking added to the assembly spreadsheetTo keep track of the module location, two
columns were added to the module assembly
spreadsheet [URL=https://docs.google.com/spreadsheets/d/12m2ESCLPH5AyWuuYV4KV1c5O_NEy7uP5PQKzVsdr3wQ/edit?usp=sharing]https://docs.google.com/spreadsheets/d/12m2ESCLPH5AyWuuYV4KV1c5O_NEy7uP5PQKzVsdr3wQ/edit?usp=sharing[/URL]
  