CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 10 of 16  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Category Subjectdown Text Attachments
  176   Thu Apr 2 22:50:33 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648All modules graded B due to mean noise > 200
electrons.
  
  181   Fri Apr 3 15:33:10 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"]All modules graded
B due to mean noise > 200 electrons.[/quote]
Correction:
  
  185   Mon Apr 6 14:23:03 2020 Andrey StarodumovFull testFT of M1645, M1646, M1647, M1648[quote="Andrey Starodumov"][quote="Andrey
Starodumov"]All modules graded B due to mean
noise > 200 electrons.[/quote]
  
  172   Wed Apr 1 17:10:16 2020 Andrey StarodumovFull testFT of M1641-M1644M1641: B due to mean noise > 200electons for
a few ROCs
M1642: B due to mean noise > 200electons
  
  169   Tue Mar 31 18:23:18 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640M1637: C. Graded C due to not completed first
test at -20C. Urs has reported issues. The
second -20C after T-Cycle and test at +10C
  
  178   Fri Apr 3 14:15:01 2020 Andrey StarodumovFull testFT of M1637, M1638, M1639, M1640[quote="Andrey Starodumov"]M1637: C. Graded
C due to not completed first test at -20C.
Urs has reported issues. The second -20C
  
  154   Fri Mar 27 18:29:53 2020 Andrey StarodumovFull testFT of M1629, M1630, M1631, M1632M1629: B due to mean noise at -20C
M1630: C due to ROC1 with all pixels failed
of PH calibration (Gain). Both FT at -20C
  
  156   Mon Mar 30 14:52:59 2020 Danek KotlinskiFull testFT of M1629, M1630, M1631, M1632I have tested M1630.
I see not problem with ROC1. See the attached
plot.
 m1630_roc1_ph_fits.png 
  157   Mon Mar 30 15:40:52 2020 UrsFull testFT of M1629, M1630, M1631, M1632M1630 is interesting because (I am using my
terminology in the following) for the test
at T=+10C ROC1 fails the PH optimization
 phval-curve_M1630_p10_C1.pdfphshot_vcal255.pdfpixelalive_C1.pdf 
  215   Wed Apr 15 17:26:46 2020 Andrey StarodumovFull testFT of M1623, M1657, M1673, M1674M1623: Grade B due to rel gain width, in ROC4
74 pixels failed trimming (Threshold) and
mean noise >200e
  
  131   Tue Mar 24 18:09:07 2020 Andrey StarodumovFull testFT of M1615, M1619, M1620, M1622Test results have been analysed with modified
code:
M1615: B
  
  137   Wed Mar 25 17:03:11 2020 Andrey StarodumovFull testFT of M1615, M1619, M1620, M1622[quote="Andrey Starodumov"]Test results have
been analysed with modified code:
M1615: B
  
  122   Fri Mar 20 18:32:34 2020 Andrey StarodumovFull testFT of M1609-M1612M1609 and M1611 are graded C
M1610 and M1612 are graded B
  
  134   Wed Mar 25 14:17:51 2020 Andrey StarodumovFull testFT of M1609, M1613, M1614, M1618 on Mar 23FT for these modules has been done on Mar
23
M1609: C
  
  190   Mon Apr 6 17:18:02 2020 Andrey StarodumovFull testFT of M1606, M1630, M1655, M1566M1606: B due to mean noise of several ROCs>
200e
M1639: C* due to failure many pixels of ROC1
  
  117   Thu Mar 19 18:01:50 2020 Andrey StarodumovFull testFT of M1605-M1608Only M1607 graded B. All others are graded
C due to trimbit test. 
M1606 should be looked carefully and may
  
  115   Wed Mar 18 17:46:07 2020 Andrey StarodumovFull testFT of M1601-M1604M1601-M1604 passed full test
M1601: grade B
M1602-M1604: Grade C. The main reason is
  
  140   Wed Mar 25 18:40:53 2020 Andrey StarodumovFull testFT of M1599, M1613, M1624, M1616M1599: B due to leakage current at +10 (2-3umA)
M1613: B due to a few pixels with bad trimmed
threshold
  
  193   Tue Apr 7 16:57:01 2020 Andrey StarodumovFull testFT of M1593, M1658, M1659, M1660M1593: B due to Rel.gain width and mean noise
of a few ROCs
M1658: B due to threshold and mean noise
  
  239   Wed Apr 29 18:11:36 2020 Andrey StarodumovFull testFT of M1590, M1592, M1596, M1600Modules tested om April 28
M1590: Grade B  Grade B due to mean noise
>200e for a few ROCs
  
ELOG V3.1.3-7933898