  212  
 | 
Tue Apr 14 17:29:46 2020 | 
Andrey Starodumov | General | ROC4 or ROC12 defects | Starting from M1650 almost every module has 
a cluster of dead pixels or broken bump bonds 
on
 | 
   | 
| 
  215  
 | 
Wed Apr 15 17:26:46 2020 | 
Andrey Starodumov | Full test | FT of M1623, M1657, M1673, M1674 | M1623: Grade B due to rel gain width, in ROC4 
74 pixels failed trimming (Threshold) and 
mean noise >200e
 | 
   | 
| 
  217  
 | 
Thu Apr 16 15:21:51 2020 | 
Andrey Starodumov | Change TBM  | Change TBMs on M1635, M1653, M1671 | M1635: no data from ROC8-ROC11 => change TBM1
 
M1653: ROC12-ROC15 not programmable => change 
TBM0
 | 
   | 
| 
  218  
 | 
Thu Apr 16 17:31:16 2020 | 
Andrey Starodumov | Full test | FT of M1662, M1675, M1676 | M1662: Grade C due to failure of ROC4 in almost 
all tests: PixelAlive, PH calibration etc
 
Should be investigated and retested. At Reception | 
   | 
| 
  219  
 | 
Fri Apr 17 18:05:45 2020 | 
Andrey Starodumov | Full test | FT of M1542, M1557, M1630, M1649 only at +10C | M1542 has grade C for relative gain width. 
Was tested with early versions of test SW 
with trim VCal=40 and not yet optimized PH | 
   | 
| 
  220  
 | 
Mon Apr 20 15:20:07 2020 | 
Andrey Starodumov | Reception test | Change TBMs on M1635, M1653, M1671 | [quote="Andrey Starodumov"]M1635: no data 
from ROC8-ROC11 => change TBM1
 
M1653: ROC12-ROC15 not programmable => change | 
   | 
| 
  221  
 | 
Mon Apr 20 17:09:12 2020 | 
Andrey Starodumov | HDI test | 4 HDIs tested | After staying in 90%+ RH 2 HDIs became flat. 
The first one was easy to mount on an HDI 
holder.
 | 
   | 
| 
  222  
 | 
Tue Apr 21 15:34:57 2020 | 
Andrey Starodumov | General | Retesting starts today | From today we will retest modules that have 
been tested with pXar SW versions earlier 
than March 18.
 | 
   | 
| 
  223  
 | 
Tue Apr 21 17:39:48 2020 | 
Andrey Starodumov | Full test | FT of M1542, M1554, M1555, M1653 | M1542: Grade C due to massive (>1000pixels 
in total) trimming failures at -20C in ROC11,14,15. 
There was no such problem at previous test | 
   | 
| 
  224  
 | 
Wed Apr 22 17:28:42 2020 | 
Andrey Starodumov | HDI test | 11 HDIs tested | After keeping HDIs in a very high RH for a 
dew hours (24 is fine) became flat and could 
be fixed on HDI holder by vacuum.
 | 
   | 
| 
  225  
 | 
Wed Apr 22 17:41:11 2020 | 
Andrey Starodumov | Full test | FT of M1542, M1554, M1555, M1653 | [quote="Andrey Starodumov"]
 
M1542: Grade C due to massive (>1000pixels 
in total) trimming failures at -20C in ROC11,14,15. | 
   | 
| 
  226  
 | 
Thu Apr 23 13:34:52 2020 | 
Andrey Starodumov | Full test | FT of M1542, M1554, M1555, M1653 | [quote="Andrey Starodumov"][quote="Andrey 
Starodumov"]
 
M1542: Grade C due to massive (>1000pixels | 
   | 
| 
  227  
 | 
Thu Apr 23 13:37:29 2020 | 
Andrey Starodumov | Full test | FT of M1556, M1557, M1559, M1560 | M1556: Grade B due to several ROCs mean noise 
>200e
 
M1557: Grade B due to several ROCs mean noise | 
   | 
| 
  228  
 | 
Thu Apr 23 17:26:51 2020 | 
Andrey Starodumov | Full test | FT of M1561, M1564, M1565, M1566 | M1561: Grade B due to several ROCs mean noise 
>200e
 
M1564: Grade B due to two ROCs mean noise | 
   | 
| 
  229  
 | 
Thu Apr 23 18:01:16 2020 | 
Andrey Starodumov | HDI test | 4 HDIs tested | The following HDIs are tested:
 
6007: OK
 
1034: Failed due to not working Channel 1 | 
   | 
| 
  230  
 | 
Fri Apr 24 13:56:11 2020 | 
Andrey Starodumov | HDI test | 3 HDIs tested | Following HDIs tested from the box "to be 
understood":
 
5021, 3019, 5008. All are fine. | 
   | 
| 
  231  
 | 
Fri Apr 24 13:59:43 2020 | 
Andrey Starodumov | Full test | FT of M1568, M1569, M1570, M1571 | M1568: Grade B due to mean noise >200e for 
a few ROCs and for ROC0 RelGainWidth(=0.1) 
is twice larger then for other ROCs
 | 
   | 
| 
  232  
 | 
Mon Apr 27 13:23:47 2020 | 
Andrey Starodumov | Full test | FT of M1573, M1574, M1576, M1577 | Test has been done on April 24
 
M1573: Grade B due to mean noise >200e for 
a few ROCs
 | 
   | 
| 
  233  
 | 
Mon Apr 27 13:50:09 2020 | 
Andrey Starodumov | Full test | FT of M1578, M1579, M1580, M1581 | M1578: Grade B due to mean noise >200e for 
a few ROCs and 67 pixels failed trimming 
in ROC1 at -20C
 | 
   | 
| 
  234  
 | 
Mon Apr 27 14:21:17 2020 | 
Andrey Starodumov | HDI test | 3 HDIs tested | # remaining HDIs from "to be understood" box 
were tested after flattening them during 
weekend in RH=99.9% box.
 | 
   |