Entry  Tue Apr 14 17:29:46 2020, Andrey Starodumov, General, ROC4 or ROC12 defects 
Starting from M1650 almost every module has a cluster of dead pixels or broken bump bonds on
ROC4 or (more often) ROC12. The number of defects varied from 20 to 40.
It's almost excluded that such damage is made at PSI, since both of us: Silvan and me, first time connected the cable
Entry  Wed Apr 15 17:26:46 2020, Andrey Starodumov, Full test, FT of M1623, M1657, M1673, M1674 
M1623: Grade B due to rel gain width, in ROC4 74 pixels failed trimming (Threshold) and mean noise >200e
M1657: Grade B due to 70 dead pixels in ROC12 and mean noise >200e
M1673: Grade B due to mean noise >200e in a few ROCs
Entry  Thu Apr 16 15:21:51 2020, Andrey Starodumov, Change TBM , Change TBMs on M1635, M1653, M1671 
M1635: no data from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change TBM0
M1671: no data from ROC12-ROC15 => change TBM0
Entry  Thu Apr 16 17:31:16 2020, Andrey Starodumov, Full test, FT of M1662, M1675, M1676 
M1662: Grade C due to failure of ROC4 in almost all tests: PixelAlive, PH calibration etc
Should be investigated and retested. At Reception PixelAlive etc was OK, only one double column showed problems
M1675: Grade B due to mean noise > 200e for several ROCs
Entry  Fri Apr 17 18:05:45 2020, Andrey Starodumov, Full test, FT of M1542, M1557, M1630, M1649 only at +10C 
M1542 has grade C for relative gain width. Was tested with early versions of test SW with trim VCal=40 and not yet optimized PH optimization/calibration.
Other modules have grade C only at +10C. This time CtrlReg=17 instead of 9 is used/
M1542: Grade B due to 61 pixels failed Threshold criteria (trimming)
    Reply  Mon Apr 20 15:20:07 2020, Andrey Starodumov, Reception test, Change TBMs on M1635, M1653, M1671 
[quote="Andrey Starodumov"]M1635: no data from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change TBM0
M1671: no data from ROC12-ROC15 => change TBM0
Entry  Mon Apr 20 17:09:12 2020, Andrey Starodumov, HDI test, 4 HDIs tested 
After staying in 90%+ RH 2 HDIs became flat. The first one was easy to mount on an HDI holder.
But after 1-2hrs the second HDI became bent again, but still remained flexible, so was also easy to mount.
I put 2 more HDIs in the same conditions and after 2 hrs was able to mount and test them.
Entry  Tue Apr 21 15:34:57 2020, Andrey Starodumov, General, Retesting starts today 
From today we will retest modules that have been tested with pXar SW versions earlier than March 18.
There were a few changes before this date: 
1) trimming VCal: 40->50
Entry  Tue Apr 21 17:39:48 2020, Andrey Starodumov, Full test, FT of M1542, M1554, M1555, M1653 
M1542: Grade C due to massive (>1000pixels in total) trimming failures at -20C in ROC11,14,15. There was no such problem at previous test when CtrlReg=9
was used, while for the present test CtrlReg=17 was used
M1554: Grade C due to massive (>1000pixels in total) trimming failures at -20C in ROC9,13. There was no such problem at previous test when CtrlReg=9 was
Entry  Wed Apr 22 17:28:42 2020, Andrey Starodumov, HDI test, 11 HDIs tested 
After keeping HDIs in a very high RH for a dew hours (24 is fine) became flat and could be fixed on HDI holder by vacuum.
11 HDIs were tested, all good:
3036, 3043, 3034, 3044, 1034, 6006, 6007, 6005,
    Reply  Wed Apr 22 17:41:11 2020, Andrey Starodumov, Full test, FT of M1542, M1554, M1555, M1653 
[quote="Andrey Starodumov"]
M1542: Grade C due to massive (>1000pixels in total) trimming failures at -20C in ROC11,14,15. There was no such problem at previous test when CtrlReg=9
was used, while for the present test CtrlReg=17 was used
    Reply  Thu Apr 23 13:34:52 2020, Andrey Starodumov, Full test, FT of M1542, M1554, M1555, M1653 
[quote="Andrey Starodumov"][quote="Andrey Starodumov"]
M1542: Grade C due to massive (>1000pixels in total) trimming failures at -20C in ROC11,14,15. There was no such problem at previous test when CtrlReg=9
was used, while for the present test CtrlReg=17 was used
Entry  Thu Apr 23 13:37:29 2020, Andrey Starodumov, Full test, FT of M1556, M1557, M1559, M1560 
M1556: Grade B due to several ROCs mean noise >200e
M1557: Grade B due to several ROCs mean noise >200e and trimming failed for 60 pixel in ROC4 at -20C
M1559: Grade A
Entry  Thu Apr 23 17:26:51 2020, Andrey Starodumov, Full test, FT of M1561, M1564, M1565, M1566 
M1561: Grade B due to several ROCs mean noise >200e
M1564: Grade B due to two ROCs mean noise >200e
M1565: Grade B due to two ROCs mean noise >200e
Entry  Thu Apr 23 18:01:16 2020, Andrey Starodumov, HDI test, 4 HDIs tested 
The following HDIs are tested:
6007: OK
1034: Failed due to not working Channel 1 in CLK0, CTR0, SDA0 and SDA1
Entry  Fri Apr 24 13:56:11 2020, Andrey Starodumov, HDI test, 3 HDIs tested 
Following HDIs tested from the box "to be understood":
5021, 3019, 5008. All are fine.
Entry  Fri Apr 24 13:59:43 2020, Andrey Starodumov, Full test, FT of M1568, M1569, M1570, M1571 
M1568: Grade B due to mean noise >200e for a few ROCs and for ROC0 RelGainWidth(=0.1) is twice larger then for other ROCs
M1569: Grade B due to mean noise >200e for a few ROCs
M1570: Grade B due to mean noise >200e for a few ROCs
Entry  Mon Apr 27 13:23:47 2020, Andrey Starodumov, Full test, FT of M1573, M1574, M1576, M1577 
Test has been done on April 24
M1573: Grade B due to mean noise >200e for a few ROCs
M1574: Grade B due to mean noise >200e for a few ROCs and trimming failed for >100 pixels and RelGainWidth too  wide for ROC0
Entry  Mon Apr 27 13:50:09 2020, Andrey Starodumov, Full test, FT of M1578, M1579, M1580, M1581 
M1578: Grade B due to mean noise >200e for a few ROCs and 67 pixels failed trimming in ROC1 at -20C
M1579: Grade A 
M1580: Grade B due to mean noise >200e for a few ROCs and 59/112 pixels failed trimming in ROC5/ROC8 at +10C
Entry  Mon Apr 27 14:21:17 2020, Andrey Starodumov, HDI test, 3 HDIs tested 
# remaining HDIs from "to be understood" box were tested after flattening them during weekend in RH=99.9% box.
6024, 4034 are OK
1039 bad: no data from A1 and A2 DTB outputs, flat output