  212   Tue Apr 14 17:29:46 2020 Andrey StarodumovGeneralROC4 or ROC12 defectsStarting from M1650 almost every module has
a cluster of dead pixels or broken bump bonds
on
  
  215   Wed Apr 15 17:26:46 2020 Andrey StarodumovFull testFT of M1623, M1657, M1673, M1674M1623: Grade B due to rel gain width, in ROC4
74 pixels failed trimming (Threshold) and
mean noise >200e
  
  217   Thu Apr 16 15:21:51 2020 Andrey StarodumovChange TBM Change TBMs on M1635, M1653, M1671M1635: no data from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change
TBM0
  
  218   Thu Apr 16 17:31:16 2020 Andrey StarodumovFull testFT of M1662, M1675, M1676M1662: Grade C due to failure of ROC4 in almost
all tests: PixelAlive, PH calibration etc
Should be investigated and retested. At Reception
  
  219   Fri Apr 17 18:05:45 2020 Andrey StarodumovFull testFT of M1542, M1557, M1630, M1649 only at +10CM1542 has grade C for relative gain width.
Was tested with early versions of test SW
with trim VCal=40 and not yet optimized PH
  
  220   Mon Apr 20 15:20:07 2020 Andrey StarodumovReception testChange TBMs on M1635, M1653, M1671[quote="Andrey Starodumov"]M1635: no data
from ROC8-ROC11 => change TBM1
M1653: ROC12-ROC15 not programmable => change
  
  221   Mon Apr 20 17:09:12 2020 Andrey StarodumovHDI test4 HDIs testedAfter staying in 90%+ RH 2 HDIs became flat.
The first one was easy to mount on an HDI
holder.
  
  222   Tue Apr 21 15:34:57 2020 Andrey StarodumovGeneralRetesting starts todayFrom today we will retest modules that have
been tested with pXar SW versions earlier
than March 18.
  
  223   Tue Apr 21 17:39:48 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653M1542: Grade C due to massive (>1000pixels
in total) trimming failures at -20C in ROC11,14,15.
There was no such problem at previous test
  
  224   Wed Apr 22 17:28:42 2020 Andrey StarodumovHDI test11 HDIs testedAfter keeping HDIs in a very high RH for a
dew hours (24 is fine) became flat and could
be fixed on HDI holder by vacuum.
  
  225   Wed Apr 22 17:41:11 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653[quote="Andrey Starodumov"]
M1542: Grade C due to massive (>1000pixels
in total) trimming failures at -20C in ROC11,14,15.
  
  226   Thu Apr 23 13:34:52 2020 Andrey StarodumovFull testFT of M1542, M1554, M1555, M1653[quote="Andrey Starodumov"][quote="Andrey
Starodumov"]
M1542: Grade C due to massive (>1000pixels
  
  227   Thu Apr 23 13:37:29 2020 Andrey StarodumovFull testFT of M1556, M1557, M1559, M1560M1556: Grade B due to several ROCs mean noise
>200e
M1557: Grade B due to several ROCs mean noise
  
  228   Thu Apr 23 17:26:51 2020 Andrey StarodumovFull testFT of M1561, M1564, M1565, M1566M1561: Grade B due to several ROCs mean noise
>200e
M1564: Grade B due to two ROCs mean noise
  
  229   Thu Apr 23 18:01:16 2020 Andrey StarodumovHDI test4 HDIs testedThe following HDIs are tested:
6007: OK
1034: Failed due to not working Channel 1
  
  230   Fri Apr 24 13:56:11 2020 Andrey StarodumovHDI test3 HDIs testedFollowing HDIs tested from the box "to be
understood":
5021, 3019, 5008. All are fine.
  
  231   Fri Apr 24 13:59:43 2020 Andrey StarodumovFull testFT of M1568, M1569, M1570, M1571M1568: Grade B due to mean noise >200e for
a few ROCs and for ROC0 RelGainWidth(=0.1)
is twice larger then for other ROCs
  
  232   Mon Apr 27 13:23:47 2020 Andrey StarodumovFull testFT of M1573, M1574, M1576, M1577Test has been done on April 24
M1573: Grade B due to mean noise >200e for
a few ROCs
  
  233   Mon Apr 27 13:50:09 2020 Andrey StarodumovFull testFT of M1578, M1579, M1580, M1581M1578: Grade B due to mean noise >200e for
a few ROCs and 67 pixels failed trimming
in ROC1 at -20C
  
  234   Mon Apr 27 14:21:17 2020 Andrey StarodumovHDI test3 HDIs tested# remaining HDIs from "to be understood" box
were tested after flattening them during
weekend in RH=99.9% box.
  