| ID | 
Date | 
Author  | 
Category | 
Subject | 
Text | 
  | 
| 
  270  
 | 
Fri May 22 16:19:01 2020 | 
Andrey Starodumov | Software | Change in MoreWeb  GradingParameters.cfg | Xray noise:
 
grade B moved from 300e to 400e
 
grade C moved from 400e to 500e | 
   | 
| 
  271  
 | 
Fri May 22 17:09:37 2020 | 
Andrey Starodumov | FTs for ETHZ | Module list1 | [COLOR=green]green[/COLOR]: correct in Total 
production overview
 
black: to remove old entries/raws
 | 
   | 
| 
  272  
 | 
Mon May 25 16:58:23 2020 | 
Andrey Starodumov | XRay HR tests | a few commments | These is just to record the information:
 
1. measured hit rates at which Efficiency 
and Xray hits Maps are taken are 40-50% of | 
   | 
| 
  273  
 | 
Mon May 25 17:24:05 2020 | 
Andrey Starodumov | Software | Change in MoreWeb ColumnUniformityPerColumn.py | In file
 
~/L1_SW/MoReWeb/Analyse/TestResultClasses/CMSPixel/QualificationGroup/XRayHRQualification$ 
emacs Chips/Chip/ColumnUniformityPerColumn/ColumnUniformityPerColumn.py
 | 
   | 
| 
  276  
 | 
Thu May 28 14:38:43 2020 | 
Andrey Starodumov | Module transfer | 18 Modules shipped to ETHZ | 1536, 1537, 1539, 1540, 1541,
 
1543, 1545, 1547, 1548, 1550,
 
1551, 1552, 1553, 1554, 1565,
 | 
   | 
| 
  277  
 | 
Thu May 28 14:40:57 2020 | 
Andrey Starodumov | Module transfer | 8 modules shipped to PSI | Quick check: Leakage current, set Vana, VthrCompCalDel 
and PixelAlive
 
Module Current@-150V Programmable Readout
 | 
   | 
| 
  278  
 | 
Fri May 29 13:56:35 2020 | 
Andrey Starodumov | Re-grading | M1630 | In ROC1 of M1630 gain calibration failed massively 
(3883 pixels) at +10C with CtrlReg 9.
 
A special test of M1630 only at +10C and | 
   | 
| 
  279  
 | 
Fri May 29 15:04:04 2020 | 
Andrey Starodumov | XRay HR tests | Analysis of HRT: M1555-M1561 and M1564 | Module            HRtest                VCal 
calibration     Grade
 
          #defects        max #noisy pix
 | 
   | 
| 
  280  
 | 
Fri May 29 15:41:40 2020 | 
Andrey Starodumov | General | M1546 | ROC10 of M1546 has 107 pixels with trimming 
problems:
 
in a VCal threshold scan after trimming 81 | 
      | 
| 
  281  
 | 
Fri May 29 15:56:27 2020 | 
Andrey Starodumov | FTs for ETHZ | Module list2 | [COLOR=green]green:[/COLOR] correct in Total 
production overview
 
black: to remove old entries/rows
 | 
   | 
| 
  284  
 | 
Thu Jun  4 15:32:50 2020 | 
Andrey Starodumov | Module transfer | 18 Modules shipped to PSI | Quick check: Leakage current, set Vana, VthrCompCalDel 
and PixelAlive
 
T=+24C
 | 
   | 
| 
  285  
 | 
Fri Jun  5 13:47:11 2020 | 
Andrey Starodumov | Module grading | M1613 | FT of this modules has been done twice: March 
23 and March 25, in both cases with the final 
test SW. On March 23 module was graded C | 
   | 
| 
  286  
 | 
Fri Jun  5 16:22:19 2020 | 
Andrey Starodumov | General | Cleaning L1_DATA directory | To be able to analyse Xray data and keep Total 
Production overview in a proper state we 
need to clean L1_DATA directory.
 | 
   | 
| 
  288  
 | 
Mon Jun 15 10:36:45 2020 | 
Andrey Starodumov | FTs for ETHZ | Module list 3 | M1596 2020-04-28 
 
M1597 2020-04-30 
 
M1598 2020-05-04 
 | 
   | 
| 
  296  
 | 
Fri Aug 14 13:47:26 2020 | 
Andrey Starodumov | General | new PH optimisation test and Total Overview | New PH optimisation is done at -20C as a FT, 
hence the results of this test are added 
to "DB" file as the second m20_1 test.
 | 
   | 
| 
  297  
 | 
Fri Aug 28 11:13:33 2020 | 
Andrey Starodumov | Module grading | M1615 | M1615: one pixel in ROC10 unmaskable hence 
should be graded C. Otherwise the module 
is of grade A
 | 
   | 
| 
  298  
 | 
Fri Aug 28 11:53:23 2020 | 
Andrey Starodumov | PhQualification | M1555 | There is no new PH optimisation for this module?!
 
To be checked! | 
   | 
| 
  299  
 | 
Fri Aug 28 12:02:48 2020 | 
Andrey Starodumov | XRay HR tests | M1599 | ROC5 has eff=93.65% and should be graded C. 
Somehow efficiency was not taken into account 
for HR test grading??? | 
   | 
| 
  300  
 | 
Fri Aug 28 14:07:24 2020 | 
Andrey Starodumov | PhQualification | M1539 | There is no new PH optimisation for this module?!
 
To be checked! | 
   | 
| 
  303  
 | 
Fri Sep 18 15:45:21 2020 | 
Andrey Starodumov | Other | M2211 and M2122 | I made a mistake and instead M2122 used ID 
M2211 in the .ini file.
 
Hence now we do not have entry for M2122 | 
   |