ID |
Date |
Author |
Category |
Subject |
Text |
 |
244
|
Thu Apr 30 17:24:57 2020 |
Dinko Ferencek | Software | MoReWeb empty DAC plots | [quote="Matej Roguljic"]Some of the DAC parameters
plots were empty in the production overview
page. All the empty plots had the number |
|
245
|
Thu Apr 30 17:33:04 2020 |
Andrey Starodumov | Software | MoReWeb empty DAC plots | [quote="Matej Roguljic"]Some of the DAC parameters
plots were empty in the total production
overview page. All the empty plots had the |
|
253
|
Thu May 7 00:10:15 2020 |
Dinko Ferencek | Software | MoReWeb empty DAC plots | [quote="Andrey Starodumov"][quote="Matej Roguljic"]Some
of the DAC parameters plots were empty in
the total production overview page. All the |
|
53
|
Fri Jan 24 18:12:00 2020 |
Dinko Ferencek | Software | MoReWeb code updates | MoReWeb code updated to include the ROC wafer
info in the XrayCalibration and XRayHRQualification
pages:
|
|
76
|
Sun Feb 9 18:36:13 2020 |
Dinko Ferencek | Module grading | Manual grading | The procedure for manual grading is described
in [URL=https://github.com/psi46/MoReWeb/pull/120]https://github.com/psi46/MoReWeb/pull/120[/URL].
|
|
303
|
Fri Sep 18 15:45:21 2020 |
Andrey Starodumov | Other | M2211 and M2122 | I made a mistake and instead M2122 used ID
M2211 in the .ini file.
Hence now we do not have entry for M2122 |
|
249
|
Mon May 4 15:28:14 2020 |
Andrey Starodumov | General | M1660 | M1660 is taken from gel-pak and cabled for
retest.
This module was graded C only at second FT |
|
183
|
Fri Apr 3 17:39:19 2020 |
Andrey Starodumov | Module doctor | M1654 | After a protection cap glued to M1654, I observed
a few strongly bent wire bonds and probably
some shorts on ROC8. One (VD+) of them is |
|
177
|
Fri Apr 3 13:55:48 2020 |
Andrey Starodumov | Reception test | M1653 failed Reception | Roc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor! |
|
173
|
Thu Apr 2 17:06:19 2020 |
Andrey Starodumov | Reception test | M1652 failed Reception | ROC1 of M1652 is not programmable.
Put in the "Bad" tray as C module. |
|
170
|
Wed Apr 1 14:36:37 2020 |
Andrey Starodumov | Reception test | M1646 failed Reception | M1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery
(between bonding pads) of ROC6.
|
|
164
|
Tue Mar 31 10:32:32 2020 |
Urs Langenegger | Full test | M1637 | Maybe M1637 has an issue: It got stuck twice
at the same place with
|
|
152
|
Fri Mar 27 17:27:09 2020 |
Andrey Starodumov | Reception test | M1635 failed Reception | All ROCs are programmable but DESER400 trailer
error bits: "NO DATA" or "IDLE DATA".
ROC8-11 are affected (no data)
|
|
242
|
Thu Apr 30 15:38:43 2020 |
danek kotlinski | Module transfer | M1635 & M1671 transferred to gel-pack | Two bad modules have been placed in gel-packs:
1635 & 1671. |
|
148
|
Fri Mar 27 14:28:14 2020 |
Andrey Starodumov | Reception test | M1633 failed Reception | All ROCs are programmable but permanent DESERALISER
ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK
|
|
210
|
Tue Apr 14 16:54:31 2020 |
Andrey Starodumov | Other | M1633 cable disconnected | We do not have any more module holders.
M1633 was in "Module doctor" tray.
I took module off the holder and put it in |
|
278
|
Fri May 29 13:56:35 2020 |
Andrey Starodumov | Re-grading | M1630 | In ROC1 of M1630 gain calibration failed massively
(3883 pixels) at +10C with CtrlReg 9.
A special test of M1630 only at +10C and |
|
130
|
Tue Mar 24 16:08:58 2020 |
Andrey Starodumov | Reception test | M1625 failed Reception | M1625: all ROCs are programmable but no readout
from ROC0-ROC3.
The same symptom as for M1623.
|
|
128
|
Tue Mar 24 15:20:18 2020 |
Andrey Starodumov | Reception test | M1623 failed Reception | M1623: all ROCs are programmable but no readout
from ROC0-ROC3.
Visual inspection is OK.
|
|
127
|
Tue Mar 24 15:18:59 2020 |
Andrey Starodumov | Reception test | M1621 failed Reception | On M1621 ROC8 is not programmable. |
|