CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 6 of 16  Not logged in ELOG logo
    Reply  Thu Apr 30 17:24:57 2020, Dinko Ferencek, Software, MoReWeb empty DAC plots 
[quote="Matej Roguljic"]Some of the DAC parameters plots were empty in the production overview page. All the empty plots had the number "35" in them (e.g.
DAC distribution m20_1 vana 35). The problem was tracked down to the trimming configuration. Moreweb was expecting us to trim to Vcal 35, while we decided
to trim to Vcal 50. I "grepped" where this was hardcoded and changed 35->50. 
    Reply  Thu Apr 30 17:33:04 2020, Andrey Starodumov, Software, MoReWeb empty DAC plots 
[quote="Matej Roguljic"]Some of the DAC parameters plots were empty in the total production overview page. All the empty plots had the number "35" in them
(e.g. DAC distribution m20_1 vana 35). The problem was tracked down to the trimming configuration. Moreweb was expecting us to trim to Vcal 35, while we
decided to trim to Vcal 50. I "grepped" where this was hardcoded and changed 35->50. 
    Reply  Thu May 7 00:10:15 2020, Dinko Ferencek, Software, MoReWeb empty DAC plots 
[quote="Andrey Starodumov"][quote="Matej Roguljic"]Some of the DAC parameters plots were empty in the total production overview page. All the empty plots
had the number "35" in them (e.g. DAC distribution m20_1 vana 35). The problem was tracked down to the trimming configuration. Moreweb was expecting us
to trim to Vcal 35, while we decided to trim to Vcal 50. I "grepped" where this was hardcoded and changed 35->50. 
Entry  Fri Jan 24 18:12:00 2020, Dinko Ferencek, Software, MoReWeb code updates 
MoReWeb code updated to include the ROC wafer info in the XrayCalibration and XRayHRQualification pages:
[URL=https://gitlab.cern.ch/CMS-IRB/MoReWeb/commit/4de8ea39050600367ae0b8e959fcc00f29be45d8]https://gitlab.cern.ch/CMS-IRB/MoReWeb/commit/4de8ea39050600367ae0b8e959fcc00f29be45d8[/URL]
Entry  Sun Feb 9 18:36:13 2020, Dinko Ferencek, Module grading, Manual grading 
The procedure for manual grading is described in [URL=https://github.com/psi46/MoReWeb/pull/120]https://github.com/psi46/MoReWeb/pull/120[/URL].

In short, inside the test folder it is necessary to place a text file called [I]grade.txt[/I] that contains just one number representing the manual grade:
Entry  Fri Sep 18 15:45:21 2020, Andrey Starodumov, Other, M2211 and M2122 
I made a mistake and instead M2122 used ID M2211 in the .ini file.
Hence now we do not have entry for M2122 but have 2 entries for M2211: one is of Sept 18 and another one called old of Sep 17).
Test results of Sep 17 are for 2211
Entry  Mon May 4 15:28:14 2020, Andrey Starodumov, General, M1660  
M1660 is taken from gel-pak and cabled for retest.
This module was graded C only at second FT at-20C, the first FT at -20C and FT at +10C give grade B. Massive trimming failure of pixels in ROC7 was not
observed.
Entry  Fri Apr 3 17:39:19 2020, Andrey Starodumov, Module doctor, M1654 
After a protection cap glued to M1654, I observed a few strongly bent wire bonds and probably some shorts on ROC8. One (VD+) of them is even detached (on
HDI side). Pads from 25/26 till 35 are affected. 
Nevertheless the Reception test gave the same results as before the cap gluing: grade A.
Entry  Fri Apr 3 13:55:48 2020, Andrey Starodumov, Reception test, M1653 failed Reception 
Roc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor!
Entry  Thu Apr 2 17:06:19 2020, Andrey Starodumov, Reception test, M1652 failed Reception 
ROC1 of M1652 is not programmable. 
Put in the "Bad" tray as C module.
Entry  Wed Apr 1 14:36:37 2020, Andrey Starodumov, Reception test, M1646 failed Reception 
M1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery (between bonding pads) of ROC6.
To module doctor! 
Entry  Tue Mar 31 10:32:32 2020, Urs Langenegger, Full test, M1637 
Maybe M1637 has an issue: It got stuck twice at the same place with 

[09:53:16.043] <TB0>     INFO:    PixTestReadback::CalibrateIa()
Entry  Fri Mar 27 17:27:09 2020, Andrey Starodumov, Reception test, M1635 failed Reception 
All ROCs are programmable but DESER400 trailer error bits: "NO DATA" or "IDLE DATA".
ROC8-11 are affected (no data)
Visual inspection is OK
Entry  Thu Apr 30 15:38:43 2020, danek kotlinski, Module transfer, M1635 & M1671 transferred to gel-pack 
Two bad modules have been placed in gel-packs: 1635 & 1671.
Entry  Fri Mar 27 14:28:14 2020, Andrey Starodumov, Reception test, M1633 failed Reception 
All ROCs are programmable but permanent DESERALISER ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK
To module doctor
Entry  Tue Apr 14 16:54:31 2020, Andrey Starodumov, Other, M1633 cable disconnected 
We do not have any more module holders. 
M1633 was in "Module doctor" tray.
I took module off the holder and put it in a gel-pak.
Entry  Fri May 29 13:56:35 2020, Andrey Starodumov, Re-grading, M1630 
In ROC1 of M1630 gain calibration failed massively (3883 pixels) at +10C with CtrlReg 9.
A special test of M1630 only at +10C and with CtrlReg 17 showed no problem.
p10_1 from ~/L1_DATA/ExtraTests_ToBeKept/M1630_FullTestp10_2020-04-17_15h54m_1587131688/000_Fulltest_p10
Entry  Tue Mar 24 16:08:58 2020, Andrey Starodumov, Reception test, M1625 failed Reception 
M1625: all ROCs are programmable but no readout from ROC0-ROC3.
The same symptom as for M1623.
Visual inspection is OK.
Entry  Tue Mar 24 15:20:18 2020, Andrey Starodumov, Reception test, M1623 failed Reception 
M1623: all ROCs are programmable but no readout from ROC0-ROC3.
Visual inspection is OK.
To module doctor. 
Entry  Tue Mar 24 15:18:59 2020, Andrey Starodumov, Reception test, M1621 failed Reception 
On M1621 ROC8 is not programmable.
ELOG V3.1.3-7933898