244
Thu Apr 30 17:24:57 2020
Dinko Ferencek
Software
MoReWeb empty DAC plots
[quote="Matej Roguljic"]Some of the DAC parameters
plots were empty in the production overview
page. All the empty plots had the number
245
Thu Apr 30 17:33:04 2020
Andrey Starodumov
Software
MoReWeb empty DAC plots
[quote="Matej Roguljic"]Some of the DAC parameters
plots were empty in the total production
overview page. All the empty plots had the
253
Thu May 7 00:10:15 2020
Dinko Ferencek
Software
MoReWeb empty DAC plots
[quote="Andrey Starodumov"][quote="Matej Roguljic"]Some
of the DAC parameters plots were empty in
the total production overview page. All the
53
Fri Jan 24 18:12:00 2020
Dinko Ferencek
Software
MoReWeb code updates
MoReWeb code updated to include the ROC wafer
info in the XrayCalibration and XRayHRQualification
pages:
76
Sun Feb 9 18:36:13 2020
Dinko Ferencek
Module grading
Manual grading
The procedure for manual grading is described
in [URL=https://github.com/psi46/MoReWeb/pull/120]https://github.com/psi46/MoReWeb/pull/120[/URL].
303
Fri Sep 18 15:45:21 2020
Andrey Starodumov
Other
M2211 and M2122
I made a mistake and instead M2122 used ID
M2211 in the .ini file.
Hence now we do not have entry for M2122
249
Mon May 4 15:28:14 2020
Andrey Starodumov
General
M1660
M1660 is taken from gel-pak and cabled for
retest.
This module was graded C only at second FT
183
Fri Apr 3 17:39:19 2020
Andrey Starodumov
Module doctor
M1654
After a protection cap glued to M1654, I observed
a few strongly bent wire bonds and probably
some shorts on ROC8. One (VD+) of them is
177
Fri Apr 3 13:55:48 2020
Andrey Starodumov
Reception test
M1653 failed Reception
Roc12-15 are not programmable.
Visual inspection is Ok, nothing found.
To module doctor!
173
Thu Apr 2 17:06:19 2020
Andrey Starodumov
Reception test
M1652 failed Reception
ROC1 of M1652 is not programmable.
Put in the "Bad" tray as C module.
170
Wed Apr 1 14:36:37 2020
Andrey Starodumov
Reception test
M1646 failed Reception
M1646 showed Idig=1A, ROC6 is not programmable.
Visual inspection: scratch on a periphery
(between bonding pads) of ROC6.
164
Tue Mar 31 10:32:32 2020
Urs Langenegger
Full test
M1637
Maybe M1637 has an issue: It got stuck twice
at the same place with
152
Fri Mar 27 17:27:09 2020
Andrey Starodumov
Reception test
M1635 failed Reception
All ROCs are programmable but DESER400 trailer
error bits: "NO DATA" or "IDLE DATA".
ROC8-11 are affected (no data)
242
Thu Apr 30 15:38:43 2020
danek kotlinski
Module transfer
M1635 & M1671 transferred to gel-pack
Two bad modules have been placed in gel-packs:
1635 & 1671.
148
Fri Mar 27 14:28:14 2020
Andrey Starodumov
Reception test
M1633 failed Reception
All ROCs are programmable but permanent DESERALISER
ERROR, Ch6 and Ch7 event ID mismatch.
Visual inspection is OK
210
Tue Apr 14 16:54:31 2020
Andrey Starodumov
Other
M1633 cable disconnected
We do not have any more module holders.
M1633 was in "Module doctor" tray.
I took module off the holder and put it in
278
Fri May 29 13:56:35 2020
Andrey Starodumov
Re-grading
M1630
In ROC1 of M1630 gain calibration failed massively
(3883 pixels) at +10C with CtrlReg 9.
A special test of M1630 only at +10C and
130
Tue Mar 24 16:08:58 2020
Andrey Starodumov
Reception test
M1625 failed Reception
M1625: all ROCs are programmable but no readout
from ROC0-ROC3.
The same symptom as for M1623.
128
Tue Mar 24 15:20:18 2020
Andrey Starodumov
Reception test
M1623 failed Reception
M1623: all ROCs are programmable but no readout
from ROC0-ROC3.
Visual inspection is OK.
127
Tue Mar 24 15:18:59 2020
Andrey Starodumov
Reception test
M1621 failed Reception
On M1621 ROC8 is not programmable.