CMS Pixel Detector Miscellaneous
Phase 1 Phase 2
Layer 1 Replacement Layers 2-4
  Layer 1 Replacement Elog, Page 2 of 16  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Category Subject Text Attachments
  295   Wed Jul 29 17:19:43 2020 danek kotlinskiPhQualificationChange configuration for PH qialificationPreparing the new PH optimization I had to
make the following modifications:
  
  304   Fri Oct 23 13:33:04 2020 danek kotlinskiModule transferL1 & L2 modules to go to P5The following modules will be transported
to CERN/P5 as spares.
  
  305   Fri Nov 6 07:28:42 2020 danek kotlinskiPOSPOS configuration files created[quote="Dinko Ferencek"]pXar parameter files
were converted to POS configuration files
by executing the following commands on the
  
  87   Mon Feb 24 13:53:32 2020 Urs LangeneggerModule assemblySetup changes in week 8Setup changes in week 8

Silvan considered the single-module gluing
  
  88   Mon Feb 24 14:01:29 2020 Urs LangeneggerModule assemblyCap gluing in W8In week 8 the following modules were glued
and tested: 
  
  89   Tue Feb 25 17:11:18 2020 Urs LangeneggerModule assemblyModules glued and tested Feb 24/25Modules glued and tested Feb 24/25

The letters after the module name indicate
  
  90   Wed Feb 26 10:34:55 2020 Urs LangeneggerFull testFulltest after Peltier replacementOn 2020/02/25, after SIlvan had replaced the
Peltiers, I did a fulltest. Here the summary:
  
  91   Thu Feb 27 09:47:51 2020 Urs LangeneggerFull testFulltest on 2020/02/26On Wednesday, 2020/02/26 the following modules
went through the full qualification procedure:
  
  93   Fri Feb 28 17:33:16 2020 Urs LangeneggerFull testFulltests on 2020/02/28M1589 B
M1590 C (gain issues?)
M1591 C (noise issues?)
  
  94   Mon Mar 2 17:39:36 2020 Urs LangeneggerFull testFulltests on 2020/03/02Modules tested: 
M1595 C
M1596 B
  
  99   Wed Mar 11 15:34:57 2020 Urs LangeneggerOtherM1586: issues with MOLEX?Module M1586 had passed the full qualification
on 20/02/27. I had had to re-insert the cable
in the Molex connector for it to become programmable.
  
  147   Fri Mar 27 10:54:04 2020 Urs LangeneggerFull testIssues with pc11366 on March 27On March 27 I had a lot of troubles getting
the full qualification up
and running.
  
  163   Tue Mar 31 09:29:02 2020 Urs LangeneggerFull testexchanged adapter for DTB_WXC03AI did not manage to get any r/o from the module
connected to that adapter, also after exchanging
the module.
  
  164   Tue Mar 31 10:32:32 2020 Urs LangeneggerFull testM1637Maybe M1637 has an issue: It got stuck twice
at the same place with 
  
  167   Tue Mar 31 17:36:36 2020 Urs LangeneggerFull testexchanged adapter for DTB_WXC03A[quote="Urs Langenegger"]I did not manage
to get any r/o from the module connected
to that adapter, also after exchanging the
  
  237   Wed Apr 29 08:48:06 2020 Urs LangeneggerOtherM1539M1539 showed no readout. I tried, all without
success, 
- reconnecting the cable to the adapter multiple
  
  294   Fri Jul 10 11:24:37 2020 Urs LangeneggerReception testproc600V3 modulesThis week I tested 12 modules built with proc600v3.
The module numbers are M1722 - M1733. 
The results are summarized at the usual place:
  
  143   Thu Mar 26 15:37:18 2020 UrsModule gradingM1606attached find the threshold difference distributions
for all four trimbits for all ROCs
 anaTrim-thrDiff-data__M1606__pxar.pdf 
  157   Mon Mar 30 15:40:52 2020 UrsFull testFT of M1629, M1630, M1631, M1632M1630 is interesting because (I am using my
terminology in the following) for the test
at T=+10C ROC1 fails the PH optimization
 phval-curve_M1630_p10_C1.pdfphshot_vcal255.pdfpixelalive_C1.pdf 
  2   Tue Aug 6 15:15:00 2019 Matej RoguljicGeneralActivities 19.6.-4.7.2019.17.6.-21.6.

Andrei and Matej were at PSI working on the
  
ELOG V3.1.3-7933898