  270   Fri May 22 16:19:01 2020 Andrey StarodumovSoftwareChange in MoreWeb GradingParameters.cfgXray noise:
grade B moved from 300e to 400e
grade C moved from 400e to 500e
  
  271   Fri May 22 17:09:37 2020 Andrey StarodumovFTs for ETHZModule list1[COLOR=green]green[/COLOR]: correct in Total
production overview
black: to remove old entries/raws
  
  272   Mon May 25 16:58:23 2020 Andrey StarodumovXRay HR testsa few commmentsThese is just to record the information:
1. measured hit rates at which Efficiency
and Xray hits Maps are taken are 40-50% of
  
  273   Mon May 25 17:24:05 2020 Andrey StarodumovSoftwareChange in MoreWeb ColumnUniformityPerColumn.pyIn file
~/L1_SW/MoReWeb/Analyse/TestResultClasses/CMSPixel/QualificationGroup/XRayHRQualification$
emacs Chips/Chip/ColumnUniformityPerColumn/ColumnUniformityPerColumn.py
  
  276   Thu May 28 14:38:43 2020 Andrey StarodumovModule transfer18 Modules shipped to ETHZ1536, 1537, 1539, 1540, 1541,
1543, 1545, 1547, 1548, 1550,
1551, 1552, 1553, 1554, 1565,
  
  277   Thu May 28 14:40:57 2020 Andrey StarodumovModule transfer8 modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
Module Current@-150V Programmable Readout
  
  278   Fri May 29 13:56:35 2020 Andrey StarodumovRe-gradingM1630In ROC1 of M1630 gain calibration failed massively
(3883 pixels) at +10C with CtrlReg 9.
A special test of M1630 only at +10C and
  
  279   Fri May 29 15:04:04 2020 Andrey StarodumovXRay HR testsAnalysis of HRT: M1555-M1561 and M1564Module            HRtest                VCal
calibration     Grade
          #defects        max #noisy pix
  
  280   Fri May 29 15:41:40 2020 Andrey StarodumovGeneralM1546ROC10 of M1546 has 107 pixels with trimming
problems:
in a VCal threshold scan after trimming 81
 C10-p10.pdfTrimBits.pdfC10-50.pdf 
  281   Fri May 29 15:56:27 2020 Andrey StarodumovFTs for ETHZModule list2[COLOR=green]green:[/COLOR] correct in Total
production overview
black: to remove old entries/rows
  
  284   Thu Jun 4 15:32:50 2020 Andrey StarodumovModule transfer18 Modules shipped to PSIQuick check: Leakage current, set Vana, VthrCompCalDel
and PixelAlive
T=+24C
  
  285   Fri Jun 5 13:47:11 2020 Andrey StarodumovModule gradingM1613FT of this modules has been done twice: March
23 and March 25, in both cases with the final
test SW. On March 23 module was graded C
  
  286   Fri Jun 5 16:22:19 2020 Andrey StarodumovGeneralCleaning L1_DATA directoryTo be able to analyse Xray data and keep Total
Production overview in a proper state we
need to clean L1_DATA directory.
  
  288   Mon Jun 15 10:36:45 2020 Andrey StarodumovFTs for ETHZModule list 3M1596 2020-04-28 
M1597 2020-04-30 
M1598 2020-05-04 
  
  296   Fri Aug 14 13:47:26 2020 Andrey StarodumovGeneralnew PH optimisation test and Total OverviewNew PH optimisation is done at -20C as a FT,
hence the results of this test are added
to "DB" file as the second m20_1 test.
  
  297   Fri Aug 28 11:13:33 2020 Andrey StarodumovModule gradingM1615M1615: one pixel in ROC10 unmaskable hence
should be graded C. Otherwise the module
is of grade A
  
  298   Fri Aug 28 11:53:23 2020 Andrey StarodumovPhQualificationM1555There is no new PH optimisation for this module?!
To be checked!
  
  299   Fri Aug 28 12:02:48 2020 Andrey StarodumovXRay HR testsM1599ROC5 has eff=93.65% and should be graded C.
Somehow efficiency was not taken into account
for HR test grading???
  
  300   Fri Aug 28 14:07:24 2020 Andrey StarodumovPhQualificationM1539There is no new PH optimisation for this module?!
To be checked!
  
  303   Fri Sep 18 15:45:21 2020 Andrey StarodumovOtherM2211 and M2122I made a mistake and instead M2122 used ID
M2211 in the .ini file.
Hence now we do not have entry for M2122
  